MULTIBELT BMP מכונות/מערכות לתעשייה תהליכית
MULTIBELT BMP — מערכת של Qlar בתחום מכונות/מערכות לתעשייה תהליכית.
הסדרה באתר Qlar (נפתח בלשונית חדשה)
הדגמים בסדרה
עמודה לכל דגם: מה שונה בין דגמי הסדרה.
| פרמטר | MULTIBELT BMP 05 eli-m-de1653d7a169e81d2003a9ec | MULTIBELT BMP 06 eli-m-5f84412825155a1879237b86 | MULTIBELT BMP 08 eli-m-790a2ba875763d36bb10e3ca | MULTIBELT BMP 10 eli-m-fa8b94257f062d13833ce5c6 | MULTIBELT BMP 12 eli-m-f88d2f096776dbd53c00afb5 | MULTIBELT BMP 14 eli-m-8aed0c04d9a38d06e8f052dd | MULTIBELT BMP 14-2 eli-m-8bc1567949b083f2ea2aad69 | MULTIBELT BMP 16-2 eli-m-0e196dc27a0f544bcbcad1cf | MULTIBELT BMP 18-2 eli-m-95ad183c12b7574ff3b4968a | MULTIBELT BMP 20-2 eli-m-5b017f579bf5534cd694779d |
|---|---|---|---|---|---|---|---|---|---|---|
| ממשקים מובנים | profinet | profinet | profinet | profinet | profinet | ethernet | ethernet | ethernet | ethernet | profinet |
| פרטי ממשק ואות לפי המקור | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| בסיס הגדרת חזרתיות | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. | Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. |
| ספיקת מסה מרבית | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h | 15000 t/h |
| בסיס קצב הדגימה | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. | The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. |
| בסיס הגדרת לינאריות | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. | Series accuracy up to ±0.5% under the documented conveyor and calibration conditions. |
| נתון טכני לפי גודל ובסיס במקור | 500 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 600 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 800 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1000 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1200 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1400 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1400 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1600 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 1800 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. | 2000 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. |
| סטטוס | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל |
התעשיות שאנו משרתים
שאלות נפוצות
תשובות לשאלות הנפוצות ביותר על המוצרים והשירותים שלנו
BMP משתמש בפלטפורמת שקילה עם מספר גלילים, במקום תחנת שקילה חד־גלילית.
הטבלה מציינת ±0.25% מהספיקה הנומינלית ו־±0.5% מהספיקה בפועל. יש לשמור על בסיס ההשוואה בכל דרישת דיוק.
קבלו הצעה או התייעצות