P8AP חיישני לחץ
P8AP — חיישנים ומכשירי מדידה של HBK בתחום חיישני לחץ.
לאתר של HBK (נפתח בלשונית חדשה)
הדגמים בסדרה
עמודה לכל דגם: מה שונה בין דגמי הסדרה.
| פרמטר | 1-P8AP/100B-001 eli-m-29d71f59c464853a25fc58a1 | 1-P8AP/10B-001 eli-m-1e97c3c33d7158f69ac28178 | 1-P8AP/200B-001 eli-m-bc383f5bb6302236d8bf5c1a | 1-P8AP/20B-001 eli-m-38ccf4ea72463d03e9c5e108 | 1-P8AP/500B-001 eli-m-6cae450a8528f9884d2e62ba | 1-P8AP/50B-001 eli-m-67371c5e35a081ed065049ed | 1-P8WT/500B-001 eli-m-03236438ec1522100d08d88f | 1-P8WT/500B-002 eli-m-709e1cac0ee27feed21d94db | K-P8AP eli-m-9e4d5a08325a58f9ef4fa8b8 |
|---|---|---|---|---|---|---|---|---|---|
| פרטי ממשק ואות לפי המקור | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| בסיס הגדרת לינאריות | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. | Official indexed accuracy class: 0.3%. |
| טמפרטורת עבודה | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C | -40–80 °C |
| ייחוס מדידת לחץ | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f | v_9030f6c8e098622f |
| מגבלת קצב בגלל קריאת המערכת | True | True | True | True | True | True | True | True | True |
| דרגת אטימות IP | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| עקרון מדידת לחץ | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure | Absolute pressure |
| בסיס קצב הדגימה | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. | The selected bridge amplifier and DAQ define the digital sample rate. |
| טווח לחץ | 0–100 bar | 0–10 bar | 0–200 bar | 0–20 bar | 0–500 bar | 0–50 bar | 0–500 bar | 0–500 bar | לא צוין |
| נתון טכני לפי גודל ובסיס במקור | 0 to 100 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 10 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 200 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 20 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 500 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 50 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 500 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 0 to 500 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable | 100 bar – 200 bar; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable |
| בסיס הגדרת חזרתיות | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. |
| יציאת חיישן לחץ | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge | Passive strain gauge |
| מחלקת דיוק / שגיאת לחץ | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) | 0.3 % (source basis mandatory) |
| טווח לחץ | לא צוין | לא צוין | לא צוין | לא צוין | לא צוין | לא צוין | לא צוין | לא צוין | לא צוין |
| סטטוס | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל | פעיל |