Thickness measurement: one sensor or two?

Whether your material is transparent decides the whole architecture.

Get new technical guides by email

On opaque material, thickness measurement needs two sensors facing each other and a frame stiff enough that the frame itself isn’t what you end up measuring. On transparent material, a single confocal sensor reads both surfaces at once and no frame is needed at all.

The frame is the hard part

In a two-sided system the C-frame is the dominant source of error. Carbon fibre and active temperature compensation exist because a steel frame that grows a few micrometres over a shift looks exactly like a change in thickness.