Data acquisition & software

Products and components for data acquisition & software.

Data acquisition & software products

70 products

Technology overview

Products and components for data acquisition & software.

Quality and certification

Certified quality management, calibration certificates and calibration services at manufacturers’ facilities.

  • Every instrument is supplied with a calibration certificate.
  • Advanced calibration services at manufacturers’ facilities abroad, coordinated and supported by Elina.
  • The quality management system is certified to ISO 9001:2015. Certificate I31417 is valid until 7 April 2028.
Download the certificate PDF
9001:2015

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Specify sensor and signal types, input count, measuring rate and synchronisation needs. Also check excitation, computer connection and control-system interface. Modular families such as QuantumX provide modules for different technologies, so total channel count alone is not sufficient.

Check the module support table and the connection diagram for the particular technology. Even a universal module may require an adapter, bridge completion or specific excitation settings. A capability of one module in a family does not automatically apply to the other modules.

When signals are analysed relative to one another in time, check synchronisation rather than only equal measuring rates. The QuantumX manual describes several synchronisation methods depending on modules and connection infrastructure. A system combining different equipment families also needs an appropriate shared time reference.

Not necessarily. QuantumX describes parallel signal paths for data analysis and real-time transfer. Transfer rate, latency and connection method must be checked separately from measuring rate. A module maximum rate is not a guarantee for every system communication path.

TEDS is an electronic transducer data sheet stored in a device in the sensor or connector. It can carry identification and calibration data that support channel configuration and traceability. Check module and connection support. Its presence does not constitute a new calibration certificate for the whole measurement chain.

Only when the module supply voltage and power budget suit the sensor. The QuantumX manual specifies adjustable supply and per-channel and per-module power limits for relevant modules. Check the combined sensor demand before selecting internal excitation or an external supply.