From the Type 4294 vibration calibration exciter series
Type 4294 vibration calibration exciter: calibrator by HBK for vibration calibrators.
Product categories
Laser triangulation
Capacitive
Inductive (eddy current)
Laser time-of-flight (TOF)
Draw-wire sensors
LVDT
Magnetic
Confocal chromatic
Interferometers
Colour & gloss measurement
Temperature sensors
Force
Weight
Torque
Noise & sound
Pressure sensors
Strain
Angle
Light intensity & surface quality
3D sensors
Confocal line scanners
Thickness measurement
Optical micrometers
Rotational speed
Laser scanners (2D/3D profile sensors)
Length measurement
Vibration and acceleration sensors
Shakers (vibration exciters)
Vibration controllers
Vibration calibrators
Software
Data acquisition
Accessories
Micro-Epsilon
Sensors and measuring systems from Germany
Qlar
Qlar (formerly Schenck Process) – weighing, feeding and flow measurement for bulk materials
Optocraft
Measuring systems for optics and lasers
Brüel & Kjær Vibro
Vibration monitoring for rotating equipment
Elovis
Non-contact systems for length and speed measurement
HBK
Load cells, strain gauges and data acquisition
HORIBA
Analytical instruments, emissions and flow control
Solutions
Vibration
Products and components for vibration calibrators.
2 matching models
From the Type 4294 vibration calibration exciter series
Type 4294 vibration calibration exciter: calibrator by HBK for vibration calibrators.
From the Type 4294 vibration calibration exciter series
Type 4294 vibration calibration exciter: calibrator by HBK for vibration calibrators.
Certified quality management, calibration certificates and calibration services at manufacturers’ facilities.
Answers to the most common questions about our products and services
It can check sensor sensitivity and the measurement chain’s response to a reference excitation. Type 4294, for example, provides excitation at 159.15 Hz.
No. A portable calibrator’s sensitivity check applies at its reference conditions. It does not by itself measure sensor response throughout the full frequency range.
A calibrator has a load limit. In the reviewed datasheet, 4294 supports up to 70 g and 4294-002 up to 200 g, with different excitation levels. Check the mounting arrangement and load on the calibrator rather than selecting by reference frequency alone.
Yes. HBK specifies higher distortion for very light loads on 4294 and 4294-002 and recommends the DB-2996 mounting disc for very light accelerometers. Treat the adaptor as part of the test conditions.
Not necessarily. The 4294 and 4294-002 datasheet defines one temperature range with a tighter reference tolerance and an extended range with a larger tolerance. Read the tolerance together with the actual test temperature.
Yes. HBK recommends periodic recalibration of 4294 to maintain accuracy and traceability, with the interval selected for the application. Using the calibrator to check transducers does not replace maintaining its own reference validity.
Tell us what you need to measure and an engineer will get back to you.