Noise & sound measurement – electroacoustics

Sound level meters

Products and components for sound level meters.

1 series in this technology
Filter products

Min 4 Hz Max 100000 Hz

Sound level meters models

3 matching models

Technology overview

Products and components for sound level meters.

Quality and certification

Certified quality management, calibration certificates and calibration services at manufacturers’ facilities.

  • Every instrument is supplied with a calibration certificate.
  • Advanced calibration services at manufacturers’ facilities abroad, coordinated and supported by Elina.
  • The quality management system is certified to ISO 9001:2015. Certificate I31417 is valid until 7 April 2028.
Download the certificate PDF
9001:2015

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The manufacturer positions 2245 as an accessible, focused Class 1 instrument and 2255 for broader, more complex acoustic work. Also match the applications and licences.

Yes. HBK’s current sound level meters support connected phone and PC workflows for control, analysis and reporting, depending on the instrument and application.

Frequency weighting, such as A or C, changes how frequencies contribute to the result. Time weighting, such as Fast or Slow, sets the response of the level measurement to changes over time. The 2255 manual defines them separately. Select both for the measurement method.

2255 distinguishes calibration from a Calibration Check. The check verifies and records the reference before and after measurement without changing the calibration. Follow the appropriate procedure and retain its record.

For timed 2255 measurements, Latched Overload is retained in the results if overload occurred at any point during the measurement. The absence of an overload now does not establish that the entire record was acquired without overload.

Allow settling according to the manual. Some 2255 results derived from Fast or Slow time weighting are valid only after settling following a reset. HBK distinguishes these from measurements such as equivalent continuous level and peak level, which are not affected by that settling.

Didn't find the answer you were looking for?

Talk to an expert

More information

Contact us

Tell us what you need to measure and an engineer will get back to you.

Send us a message

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words