LAN-XI 3052 High-frequency Input Module Data acquisition systems

LAN-XI 3052 High-frequency Input Module: data acquisition systems by HBK.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of LAN-XI 3052 High-frequency Input Module
ADC sampling rate 262000 samples/s
תחום כניסה במתח שיא 10 V
שגיאת אמפליטודה ב-dB 0.05 dB
DAQ input RMS noise 0.000004 V

Models in the series

One column per model: what differs between the models of the series.

Models of LAN-XI 3052 High-frequency Input Module compared by parameter
Parameter -3052-A-030-R eli-m-af1ff2036801ef9d04b7895b -3052-A-030-X eli-m-4b99271a1841d0496fb333cd
ADC sampling rate 262000 samples/s 262000 samples/s
תחום כניסה במתח שיא 10 V 10 V
שגיאת אמפליטודה ב-dB Not specified Not specified
DAQ input RMS noise Maximum rate with a compatible controller Not specified Not specified
source_repeatability_basis System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. System repeatability depends on the configured transducer, excitation, range, synchronization and calibration.
ADC resolution 24 bit 24 bit
Number of measurement channels 3 3
data_transfer_bits 24 bit 24 bit
source_linearity_basis Accuracy depends on the selected input and range. Accuracy depends on the selected input and range.
source_controller_shock_resistance_test_g 100 g 100 g
Interfaces ethernet ethernet
source_sampling_rate_basis Official indexed maximum sample-rate selection: 262,000 Hz. Official indexed maximum sample-rate selection: 262,000 Hz.
source_controller_magnetic_field_immunity_am_per_m EN/IEC 61000-4-8, 30 A/m EN/IEC 61000-4-8, 30 A/m
adc_converter_count 2 2
quantity_specification Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: None; Housing: Frame; Interfaces: TCP/IP Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: None; Housing: Frame; Interfaces: TCP/IP
Operating temperature -10–55 °C -10–55 °C
Protection class (DIN EN 60529) ip31 ip31
Frequency response 0–102400 Hz 0–102400 Hz
Storage temperature -25–70 °C -25–70 °C
Status Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It targets high-frequency measurements, with three inputs and a documented frequency range from DC to 102.4 kHz.

No. In the reviewed brochure it is the input frequency-range limit. Sampling rate must be checked separately for the acquisition setup.

The table lists a UA-2100-030 panel and three BNC connectors. An alternative panel requires module and signal compatibility.

The documented interface requires a charge-to-CCLD converter. A BNC connector alone does not establish direct charge-input capability.

It is the manufacturer’s module dynamic-range figure for demanding measurements. It is neither sensor resolution nor a percentage measurement error.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words