LAN-XI 3052 High-frequency Input Module Data acquisition systems
LAN-XI 3052 High-frequency Input Module: data acquisition systems by HBK.
Visit the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| ADC sampling rate | 262000 samples/s |
|---|---|
| תחום כניסה במתח שיא | 10 V |
| שגיאת אמפליטודה ב-dB | 0.05 dB |
| DAQ input RMS noise | 0.000004 V |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | -3052-A-030-R eli-m-af1ff2036801ef9d04b7895b | -3052-A-030-X eli-m-4b99271a1841d0496fb333cd |
|---|---|---|
| ADC sampling rate | 262000 samples/s | 262000 samples/s |
| תחום כניסה במתח שיא | 10 V | 10 V |
| שגיאת אמפליטודה ב-dB | Not specified | Not specified |
| DAQ input RMS noise Maximum rate with a compatible controller | Not specified | Not specified |
| source_repeatability_basis | System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. | System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. |
| ADC resolution | 24 bit | 24 bit |
| Number of measurement channels | 3 | 3 |
| data_transfer_bits | 24 bit | 24 bit |
| source_linearity_basis | Accuracy depends on the selected input and range. | Accuracy depends on the selected input and range. |
| source_controller_shock_resistance_test_g | 100 g | 100 g |
| Interfaces | ethernet | ethernet |
| source_sampling_rate_basis | Official indexed maximum sample-rate selection: 262,000 Hz. | Official indexed maximum sample-rate selection: 262,000 Hz. |
| source_controller_magnetic_field_immunity_am_per_m | EN/IEC 61000-4-8, 30 A/m | EN/IEC 61000-4-8, 30 A/m |
| adc_converter_count | 2 | 2 |
| quantity_specification | Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: None; Housing: Frame; Interfaces: TCP/IP | Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: None; Housing: Frame; Interfaces: TCP/IP |
| Operating temperature | -10–55 °C | -10–55 °C |
| Protection class (DIN EN 60529) | ip31 | ip31 |
| Frequency response | 0–102400 Hz | 0–102400 Hz |
| Storage temperature | -25–70 °C | -25–70 °C |
| Status | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It targets high-frequency measurements, with three inputs and a documented frequency range from DC to 102.4 kHz.
No. In the reviewed brochure it is the input frequency-range limit. Sampling rate must be checked separately for the acquisition setup.
The table lists a UA-2100-030 panel and three BNC connectors. An alternative panel requires module and signal compatibility.
The documented interface requires a charge-to-CCLD converter. A BNC connector alone does not establish direct charge-input capability.
It is the manufacturer’s module dynamic-range figure for demanding measurements. It is neither sensor resolution nor a percentage measurement error.