Skip to content

LAN-XI 3053 12-channel Input Module Data acquisition systems

LAN-XI 3053 12-channel Input Module: data acquisition systems by HBK.

Visit the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of LAN-XI 3053 12-channel Input Module compared by parameter
Parameter -3053-B-120-R eli-m-6e31a4dc8433a65abd8e3586 -3053-B-120-X eli-m-92d0a3d0043cf74cf01dc187
source_linearity_basis Accuracy depends on the selected input and range. Accuracy depends on the selected input and range.
source_repeatability_basis System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. System repeatability depends on the configured transducer, excitation, range, synchronization and calibration.
Protection class (DIN EN 60529) ip31 ip31
Interfaces ethernet ethernet
Operating temperature -10–55 °C -10–55 °C
source_sampling_rate_basis Official indexed maximum sample-rate selection: 65,500 Hz. Official indexed maximum sample-rate selection: 65,500 Hz.
source_controller_magnetic_field_immunity_am_per_m EN/IEC 61000-4-8, 30 A/m EN/IEC 61000-4-8, 30 A/m
Number of measurement channels 12 12
quantity_specification Inputs: Standardized voltage (+/- 10V), IEPE / CCLD; Outputs: None; Housing: Frame; Interfaces: TCP/IP Inputs: Standardized voltage (+/- 10V), IEPE / CCLD; Outputs: None; Housing: Frame; Interfaces: TCP/IP
source_controller_shock_resistance_test_g 100 g 100 g
Storage temperature -25–70 °C -25–70 °C
ADC sampling rate 65500 samples/s 65500 samples/s
Status Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It combines twelve sound and vibration inputs in a compact module for applications requiring many channels.

The table specifies UA-2107-120 with SMB connectors. These are not the BNC connectors used on some other LAN-XI modules.

The table specifies DC to 25.6 kHz. This describes the input frequency range of the stated configuration, not its sampling rate.

The table lists direct voltage and CCLD. Charge sensors require a charge-to-CCLD converter under the manufacturer’s footnote.

No. A single 3053 provides twelve inputs and can operate as a stand-alone acquisition front end within the LAN-XI architecture.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words