LAN-XI 3161 High-frequency Input/Output Module Data acquisition systems
LAN-XI 3161 High-frequency Input/Output Module: data acquisition systems by HBK.
Visit the HBK site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | -3161-A-011-R eli-m-ddf85b8e0e3f530e4f216d7a | -3161-A-011-X eli-m-be50b0d60223cbd958cd1f72 |
|---|---|---|
| Operating temperature | -10–55 °C | -10–55 °C |
| Protection class (DIN EN 60529) | ip31 | ip31 |
| source_linearity_basis | Accuracy depends on the selected input and range. | Accuracy depends on the selected input and range. |
| Number of measurement channels | 1 | 1 |
| source_controller_shock_resistance_test_g | 100 g | 100 g |
| quantity_specification | Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP | Inputs: Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones; Outputs: Voltage (+/- 10V); Housing: Frame; Interfaces: TCP/IP |
| Storage temperature | -25–70 °C | -25–70 °C |
| source_controller_magnetic_field_immunity_am_per_m | EN/IEC 61000-4-8, 30 A/m | EN/IEC 61000-4-8, 30 A/m |
| source_repeatability_basis | System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. | System repeatability depends on the configured transducer, excitation, range, synchronization and calibration. |
| source_sampling_rate_basis | Official indexed maximum sample-rate selection: 524,000 Hz. | Official indexed maximum sample-rate selection: 524,000 Hz. |
| Interfaces | ethernet | ethernet |
| ADC sampling rate | 524000 samples/s | 524000 samples/s |
| Status | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The manufacturer presents a high-frequency input/output module for applications such as transducer calibration and underwater measurements. It has one measurement input and one generator output channel.
Both described input and output channels cover DC to 204.8 kHz. This is channel frequency range, not ADC sampling rate.
No. The table describes one input channel with alternative connections, including BNC, circular and TNC connectors. Each connector must not be counted as an extra channel.
The panel provides direct/CCLD, 200 V microphone-polarization and charge options. Select the input path appropriate to the transducer.
The source lists Types 8103, 8104, 8105 and 8106. Other hydrophones require interface and specification checks.