Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSF
Measuring window 0–8 mm
Measuring range 1–6 mm
active_area_length 35–105 mm
Recommended target width 50–128 mm
active_area_width 1.5–70 mm
Linearity 4–12 µm
Weight 0.005–0.08 kg
Resolution 0.0006–0.12 µm
Number of measurement channels 1–8
Recommended target height 13–25 mm
Accuracy 4–12 µm
ADC sampling rate 1000–8500 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSF compared by parameter
Parameter CSF2 eli-m-91b358bee9ee510d218ad8d5 CSF2-CRg4.0 eli-m-d84b5a05dfc52a8bc17034db CSF4 eli-m-63f6e9287c47318579d22f89 CSF4-CRg4.0 eli-m-d7ea6d7550b2daf42e71ba07 CSF6 eli-m-db2171edff862a39bfbd4456 CSF6-CRg4.0 eli-m-57bd0c1c157e43f4e1e7c8fe
Measuring window 0–1 mm 0–2 mm 0–8 mm 0–8 mm 0–6 mm 0–3 mm
Measuring range 1 mm 2 mm 4 mm 4 mm 6 mm 6 mm
active_area_length 35 mm 35 mm 70 mm 70 mm 105 mm 105 mm
source_sensor_form Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB Flat / strip / PCB
Recommended target width 50 mm 50 mm 90 mm 90 mm 128 mm 128 mm
active_area_width 1.5 mm 35 mm 70 mm 70 mm 1.5 mm 1.5 mm
Linearity 4 µm 4 µm 8 µm 8 µm 12 µm 12 µm
Weight 0.005 kg 0.075 kg 0.007 kg 0.077 kg 0.01 kg 0.08 kg
source_gap_measurement_mode Single-sided gap one-sided gap measurement Single-sided gap one-sided gap measurement one-sided gap measurement Single-sided gap
Resolution 0.0005999999999999999 µm 0.03999999999999999 µm 0.0012 µm 0.0012 µm 0.12 µm 0.0018 µm
Number of measurement channels 4 4 4 4 8 1
Recommended target height 13 mm 13 mm 16.5 mm 16.5 mm 25 mm 25 mm
Interfaces ethernet ethercat ethercat profinet ethercat profinet
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40 ip40 ip40
Operating temperature -40–100 °C -40–100 °C -40–100 °C -40–100 °C -40–100 °C -40–100 °C
interface_specification Analog 0-10V Analog 0-10V Analog 0-10V RS422 / RS485 RS422 / RS485 Analog 0-10V
Storage temperature -40–100 °C -40–100 °C -40–100 °C -40–100 °C -40–100 °C -40–100 °C
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6530 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6230 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6220 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution.
source_temperature_stability_um_per_k -0.2 µm/K -0.2 µm/K -0.5 µm/K -0.5 µm/K -0.9 µm/K -0.9 µm/K
source_sampling_rate_basis DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s DL6220: 5 kHz bandwidth; DT6220 digital rate 3.906 kSamples/s DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors
active_area_height 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm
quantity_specification 0-2 mm sensor range; effective gap range is 0-2 mm 0-2 mm sensor range; effective gap range is 0-2 mm 0-4 mm sensor range; effective gap range is 0-4 mm 0-4 mm sensor range; effective gap range is 0-4 mm 0-6 mm sensor range; effective gap range is 0-6 mm 0-6 mm sensor range; effective gap range is 0-6 mm
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 4 µm 4 µm 8 µm 8 µm 12 µm 12 µm
ADC sampling rate 1000 samples/s 2000 samples/s 8500 samples/s 5000 samples/s 5000 samples/s 5000 samples/s
Status Active Active Active Active Active Active
Datasheet PDF — CSF2 (opens in a new tab) PDF — CSF2-CRg4.0 (opens in a new tab) PDF — CSF4 (opens in a new tab) PDF — CSF4-CRg4.0 (opens in a new tab) PDF — CSF6 (opens in a new tab) PDF — CSF6-CRg4.0 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a flat, one-sided head with nominal 2, 4 or 6 mm spans. Measuring span differs from the physical clearance needed to insert it.

The manufacturer recommends it only for portable measurements. Continuous installation uses bonding of the sensor underside according to the instructions.

No. Standard variants have a type E triaxial socket; CRg4.0 variants include a 4 m cable with a type B connector. These are distinct connection configurations.

The table lists at least 0.75 mm required gap width. Also account for mounting method and the sensor drawing.

It specifies a recommended rectangular target that varies with model span. Active-strip width must not be treated as the complete target-size requirement.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words