Skip to content

capaNCDT CSH/FL/SE Capacitive

capaNCDT CSH/FL/SE: sensors and measurement devices by Micro-Epsilon for capacitive.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSH/FL/SE
Linearity 0.25–15 µm
Measuring range 0.125–6 mm
Measuring window 0–6 mm
Resolution 0.000075–0.06 µm
active_area_published_size 2.9–13 mm
Number of measurement channels 1–8
Recommended target diameter 5–30 mm
Weight 0.028–0.037 kg
ADC sampling rate 1000–8500 samples/s
Accuracy 0.25–15 µm

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSH/FL/SE compared by parameter
Parameter CSH-0,25/FL/SE/CRm-1,4 eli-m-fda4d3bb60997465ba47a3d6 CSH-0,5/FL/SE/CRm-1,4 eli-m-48c626360e2ff13d79684e1b CSH-1,2/FL/SE/CRm-1,4 eli-m-68423c43fa840df6633a9601 CSH-1/FL/SE/CRm-1,4 eli-m-12fbde90119268ef231ee665 CSH-2/FL/SE/CRm-1,4 eli-m-e0054949f43c57e374e8a561 CSH-3/FL/SE/CRm-1,4 eli-m-9a429c8cb42493763585e361 CSH-5/FL/SE/CRm-1,4 eli-m-61ef25449da5e0c46b64efa2
Linearity 0.25 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm 1.5 µm 15 µm
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm
source_sampling_rate_basis DT6112 high-speed controller: 20 kHz bandwidth DL6220: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s DL6220: 5 kHz bandwidth; DT6240 digital rate 3.906 kSamples/s DT6110: 1 kHz analog measurement bandwidth DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system DL6510 with CP6001: 8.5 kHz bandwidth in the official maximum-two-channel DT6530 base system DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth
interface_specification Analog 0-10V 4-20mA 4-20mA Analog 0-10V Analog 0-10V Analog 0-10V 4-20mA
Measuring range 0.125 mm 0.25 mm 1.2 mm 1 mm 4 mm 6 mm 5 mm
Interfaces ethernet ethercat ethercat ethernet ethercat profinet ethernet
Protection class (DIN EN 60529) ip40 ip40 ip40 ip40 ip40 ip40 ip40
Measuring window 0–0.25 mm 0–1 mm 0–0.6 mm 0–0.5 mm 0–1 mm 0–6 mm 0–2.5 mm
Operating temperature -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C
source_linearity_basis Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6120/IP controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6220 + DL6230 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6240 + DL6230 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6238 + DL6228 controller contribution.
Resolution 7.499999999999999e-05 µm 0.00015 µm 0.00036 µm 0.0003 µm 0.0005999999999999999 µm 0.05999999999999999 µm 0.0015 µm
quantity_specification 0-0.25 mm model-level measuring interval 0-0.5 mm model-level measuring interval 0-1.2 mm model-level measuring interval 0-1 mm model-level measuring interval 0-2 mm model-level measuring interval 0-3 mm model-level measuring interval 0-5 mm model-level measuring interval
active_area_published_size 2.9 mm 4.1 mm 6.3 mm 5.7 mm 8.1 mm 10 mm 13 mm
Number of measurement channels 1 4 2 8 1 4 4
Recommended target diameter 5 mm 7 mm 11 mm 11 mm 17 mm 24 mm 30 mm
Storage temperature -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C
Weight 0.028 kg 0.028 kg 0.03 kg 0.03 kg 0.037 kg 0.037 kg 0.037 kg
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 5000 samples/s 5000 samples/s 8500 samples/s 2000 samples/s 8500 samples/s 1000 samples/s 8500 samples/s
Accuracy 0.25 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm 1.5 µm 15 µm
Status Active Active Active Active Active Active Active
Datasheet PDF — CSH-0,25/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-0,5/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-1,2/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-1/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-2/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-3/FL/SE/CRm-1,4 (opens in a new tab) PDF — CSH-5/FL/SE/CRm-1,4 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CSH/FL/SE uses a flat rather than cylindrical design. It also addresses vacuum, cleanroom and strong-magnetic-field environments.

No. Recommended flat-target size depends on model span and differs from active area. Use the model column, not the smallest family value.

Yes. The table distinguishes front and rear mounting temperature coefficients. Hole count and type also depend on model.

It specifies an integral 1.4 m cable with a type B connector. Other cables, feedthroughs and controller must also match the special environment.

No. Its explicit rating is IP40. Housing material and special-environment suitability do not increase that rating.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words