Skip to content

capaNCDT DT61xx controllers Capacitive

capaNCDT DT61xx controllers: measurement controllers by Micro-Epsilon for capacitive.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT DT61xx controllers
Operating temperature -20–60 °C
Storage temperature -20–75 °C
Linearity (% FSO) 0.05–0.1 %
Resolution (% FSO) 0.0007–0.0014 %

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT DT61xx controllers compared by parameter
Parameter DT6110 eli-m-3a9a07a0e16c8d276da5c3ec DT6110/IP eli-m-bb97255d2237f1b4fead83d4 DT6112 eli-m-363afdc0101726a3c7386066 DT6120 eli-m-d469830ad426a1ff0a6d310c DT6120/IP eli-m-6bd760f9ed329b48dd8bb009
Protection class (DIN EN 60529) ip40 ip68 ip40 ip40 ip68
Operating temperature 10–60 °C -20–60 °C 10–60 °C 10–60 °C -20–60 °C
Storage temperature -10–75 °C -20–75 °C -10–75 °C -10–75 °C -20–75 °C
Number of measurement channels 1 1 1 1 1
Linearity (% FSO) 0.05 % 0.1 % 0.1 % 0.05 % 0.1 %
Resolution (% FSO) 0.0007 % 0.0009 % 0.0014 % 0.0007 % 0.0009 %
Interfaces Not specified Not specified Not specified rs485 rs485
Output update rate Not specified Not specified Not specified 2000 Hz 2000 Hz
Status Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. DT6110/DT6112 are analog paths, while DT6120 adds RS485. /IP variants and output configurations must also be selected by model.

No. It is the analog path’s −3 dB frequency response. Digital output rate is separately specified for supporting models such as DT6120.

No. Standard versions specify IP40; /IP versions specify IP68. Match the cable and connection to the variant.

No. The manufacturer defines channel linearity as the sum of controller and sensor linearity. Match bandwidth and measuring span as well.

The table specifies one measurement channel. Multiple heads require separate controllers or a suitable multichannel system; auxiliary connections are not extra measurement channels.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words