capaNCDT DT61xx controllers Capacitive
capaNCDT DT61xx controllers: measurement controllers by Micro-Epsilon for capacitive.
Visit the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -20–60 °C |
|---|---|
| Storage temperature | -20–75 °C |
| Linearity (% FSO) | 0.05–0.1 % |
| Resolution (% FSO) | 0.0007–0.0014 % |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DT6110 eli-m-3a9a07a0e16c8d276da5c3ec | DT6110/IP eli-m-bb97255d2237f1b4fead83d4 | DT6112 eli-m-363afdc0101726a3c7386066 | DT6120 eli-m-d469830ad426a1ff0a6d310c | DT6120/IP eli-m-6bd760f9ed329b48dd8bb009 |
|---|---|---|---|---|---|
| Protection class (DIN EN 60529) | ip40 | ip68 | ip40 | ip40 | ip68 |
| Operating temperature | 10–60 °C | -20–60 °C | 10–60 °C | 10–60 °C | -20–60 °C |
| Storage temperature | -10–75 °C | -20–75 °C | -10–75 °C | -10–75 °C | -20–75 °C |
| Number of measurement channels | 1 | 1 | 1 | 1 | 1 |
| Linearity (% FSO) | 0.05 % | 0.1 % | 0.1 % | 0.05 % | 0.1 % |
| Resolution (% FSO) | 0.0007 % | 0.0009 % | 0.0014 % | 0.0007 % | 0.0009 % |
| Interfaces | Not specified | Not specified | Not specified | rs485 | rs485 |
| Output update rate | Not specified | Not specified | Not specified | 2000 Hz | 2000 Hz |
| Status | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. DT6110/DT6112 are analog paths, while DT6120 adds RS485. /IP variants and output configurations must also be selected by model.
No. It is the analog path’s −3 dB frequency response. Digital output rate is separately specified for supporting models such as DT6120.
No. Standard versions specify IP40; /IP versions specify IP68. Match the cable and connection to the variant.
No. The manufacturer defines channel linearity as the sum of controller and sensor linearity. Match bandwidth and measuring span as well.
The table specifies one measurement channel. Multiple heads require separate controllers or a suitable multichannel system; auxiliary connections are not extra measurement channels.
Get a quote or advice