Skip to content

ds822 hazardous-area 4 mm eddy-current displacement system Inductive (eddy current)

ds822 hazardous-area 4 mm eddy-current displacement system: sensors and measurement devices by Brüel & Kjær Vibro for inductive (eddy current).

Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of ds822 hazardous-area 4 mm eddy-current displacement system compared by parameter
Parameter ds822.mc301/1 (configurable) eli-m-641e99b1ddc233b178ca8bc6 ds822.mc301/2 (configurable) eli-m-437efb6a50d49c01a52dfce8 ds822.mc301/3 (configurable) eli-m-f2f40b7a4efaa0235efae88c ds822.mc301/4 (configurable) eli-m-012c596fbc873bcad30b039f
Frequency response 0–10000 Hz 0–10000 Hz 0–10000 Hz 0–10000 Hz
Operating temperature -55–180 °C -55–180 °C -55–180 °C -55–180 °C
Contact Non-contact Non-contact Non-contact Non-contact
Status Active Active Active Active
Datasheet PDF — ds822.mc301/1 (configurable) (opens in a new tab) PDF — ds822.mc301/2 (configurable) (opens in a new tab) PDF — ds822.mc301/3 (configurable) (opens in a new tab) PDF — ds822.mc301/4 (configurable) (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a net linear displacement span of 4 mm at approximately 0.5–4.5 mm target distance from the probe. It uses eddy-current measurement against conductive material, with DC to 10 kHz at −3 dB.

It requires a probe with integrated cable and a matching od13x driver; a separate connection cable is added according to system length. The red colour code identifies the range family, but component and configuration codes must also match.

Documented nominal system lengths are 5 or 10 m. Select probe cable and connection cable together for the matching total system length; do not add a generic cable without checking the configuration.

No. Sensitivity error and deviation from the reference line are specified by system length and temperature. Calibration data refer to 42CrMo4, so also check the actual shaft material.

Select the complete chain under the Ex certificate and temperature class. Sensor and cable limits differ from oscillator limits; the general probe temperature range does not approve the whole system for that range.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words