eddyNCDT 3005 Inductive (eddy current)
eddyNCDT 3005: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -20–70 °C |
|---|---|
| Minimum target diameter | 24–72 mm |
| End of measuring range | 1.1–6.6 mm |
| Start of measuring range | 0.1–0.6 mm |
| Resolution | 0.5–3 µm |
| Linearity | 2.5–15 µm |
| Working distance | 0.1–6.6 mm |
| Weight | 0.07–0.095 kg |
| Measuring range | 1–6 mm |
| Repeatability | 0.5–3 µm |
| Accuracy | 2.5–15 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DT3005-S2-A-C1 eli-m-e1d6abdaf607a8f0dc332c25 | DT3005-S2-M-C1 eli-m-ae179f17075df9b4af18e3bc | DT3005-U1-A-C1 eli-m-8f31bc9f8883439dd695bb59 | DT3005-U1-M-C1 eli-m-71cbe226dbedf57cb8670ec6 | DT3005-U3-A-C1 eli-m-eb2742edb7636b77504ee0b0 | DT3005-U3-M-C1 eli-m-216cd1a38c9d0e363bd2a728 | DT3005-U6-A-C1 eli-m-c362b6dec631ca1cab79ce1c | DT3005-U6-M-C1 eli-m-b251ce2be0bd13ef5e775125 |
|---|---|---|---|---|---|---|---|---|
| Operating temperature | -20–125 °C | -20–125 °C | -20–125 °C | -20–125 °C | -20–125 °C | -20–125 °C | -20–125 °C | -20–125 °C |
| interface_specification | Digital I/O | RS422 / RS485 | Analog 0-10V | Analog 0-10V | Digital I/O | 4-20mA | Analog 0-10V | 4-20mA |
| source_sampling_rate_basis | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth |
| quantity_specification | 0-2 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-1 mm model-level measuring interval | 0-1 mm model-level measuring interval | 0-3 mm model-level measuring interval | 0-3 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-6 mm model-level measuring interval |
| source_calibrated_target_material | "Aluminum" | "Steel" | "Aluminum" | "Steel" | "Aluminum" | "Steel" | "Aluminum" | "Steel" |
| Interfaces | ethernet | ethernet | ethercat | ethercat | ethernet | ethernet | ethercat | ethercat |
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| Minimum target diameter | 24 mm | 24 mm | 24 mm | 24 mm | 48 mm | 48 mm | 72 mm | 72 mm |
| End of measuring range | 2.2 mm | 2.2 mm | 1.1 mm | 1.1 mm | 3.3 mm | 3.3 mm | 6.6 mm | 6.6 mm |
| Number of measurement channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Start of measuring range | 0.2 mm | 0.2 mm | 0.1 mm | 0.1 mm | 0.3 mm | 0.3 mm | 0.6 mm | 0.6 mm |
| Resolution | 1 µm | 1 µm | 0.5 µm | 0.5 µm | 1.5 µm | 1.5 µm | 3 µm | 3 µm |
| Linearity | 5 µm | 5 µm | 2.5 µm | 2.5 µm | 7.5 µm | 7.5 µm | 15 µm | 15 µm |
| Working distance | 0.2–2.2 mm | 0.2–2.2 mm | 0.1–1.1 mm | 0.1–1.1 mm | 0.3–3.3 mm | 0.3–3.3 mm | 0.6–6.6 mm | 0.6–6.6 mm |
| Upper cutoff frequency | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz | 5000 Hz |
| Weight | 0.075 kg | 0.075 kg | 0.07000000000000001 kg | 0.07000000000000001 kg | 0.077 kg | 0.077 kg | 0.095 kg | 0.095 kg |
| source_sensor_temperature_stability_microns_per_k | 0.5 | 0.5 | 0.25 | 0.25 | 0.75 | 0.75 | 1.5 | 1.5 |
| Cable length | 1 m | 1 m | 1 m | 1 m | 1 m | 1 m | 1 m | 1 m |
| Supply voltage | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V | 12–32 V |
| source_sensor_shielding | "shielded" | "shielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" |
| Measuring range | 2 mm | 2 mm | 1 mm | 1 mm | 3 mm | 3 mm | 6 mm | 6 mm |
| Repeatability | 1 µm | 1 µm | 0.5 µm | 0.5 µm | 1.5 µm | 1.5 µm | 3 µm | 3 µm |
| Storage temperature | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C |
| Accuracy | 5 µm | 5 µm | 2.5 µm | 2.5 µm | 7.5 µm | 7.5 µm | 15 µm | 15 µm |
| ADC sampling rate | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s | 75000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — DT3005-S2-A-C1 (opens in a new tab) | PDF — DT3005-S2-M-C1 (opens in a new tab) | PDF — DT3005-U1-A-C1 (opens in a new tab) | PDF — DT3005-U1-M-C1 (opens in a new tab) | PDF — DT3005-U3-A-C1 (opens in a new tab) | PDF — DT3005-U3-M-C1 (opens in a new tab) | PDF — DT3005-U6-A-C1 (opens in a new tab) | PDF — DT3005-U6-M-C1 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It comprises a sensor head, integral sensor cable and compact controller calibrated for the target material. Specify head, range and material together.
No. The specified analog update is 75 kHz, digital update 1 kHz and frequency response 5 kHz. These are three distinct quantities.
RS485 is native. The listed Industrial Ethernet connections require a compatible interface module; they are not onboard every controller.
No. The standard head operates at −20 to 125°C, versus −20 to 70°C for the controller. A head rated to 180°C is a separate option.
No. Preserve the specified plugged-connector conditions. A pressure rating for the controller front is not a rating for every side and connection.
Get a quote or advice
Tell us what you need and an engineer will come back to you.