| Parameter | ES-S04-C-CAx/mB0/D2,0 |
|---|---|
| Cable diameter | 2 mm |
| Status | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Its net span is 0.4 mm with a 0.04 mm start offset, giving 0.04–0.44 mm from the head face.
The 0.02 µm value applies with DT307x, static 20 Hz bandwidth and mid-range. It is not automatically the maximum-bandwidth resolution.
Tabulated linearity requires DT307x and three- or five-point linearization. Preserve the head, cable and calibration combination.
No. The table specifies IP50 alongside 100 bar front-side pressure resistance. These are separate ratings.
Also check connection, bending radius and minimum flat target diameter of 5 mm. Integral and extension cables are specified separately.