eddyNCDT ES sensor heads Inductive (eddy current)
eddyNCDT ES sensor heads: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
Visit the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Resolution | 0.04–0.32 µm |
|---|---|
| Start of measuring range | 0.1–0.8 mm |
| Minimum target diameter | 12–72 mm |
| Operating temperature | -20–200 °C |
| End of measuring range | 1.1–8.8 mm |
| Accuracy | 1–16 µm |
| Working distance | 0.1–8.8 mm |
| Weight | 0.0024–0.062 kg |
| Storage temperature | -20–200 °C |
| Measuring range | 1–8 mm |
| Linearity | 2–16 µm |
| ADC sampling rate | 80000–200000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ES-S1 eli-m-35f10df59aa3d5626c810881 | ES-S2 eli-m-dfbcd2d42e8ef3c05864d0cc | ES-S4 eli-m-1c51ce54617ebe076578ecb6 | ES-U1 eli-m-25b1d4ed846da8a7d4f494a8 | ES-U2 eli-m-5d0e2093e520fc4d48e34479 | ES-U3 eli-m-b9a7e7cf8b0719bc5be1c8e5 | ES-U6 eli-m-551942675c5984eb965f783a | ES-U8 eli-m-ecfe8d6d5e2bffe653ec3c6e |
|---|---|---|---|---|---|---|---|---|
| quantity_specification | 0-1 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-4 mm model-level measuring interval | 0-1 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-3 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-8 mm model-level measuring interval |
| Protection class (DIN EN 60529) | ip67 | ip68 | ip68 | ip67 | ip67 | ip68 | ip68 | ip67 |
| Interfaces | usb | usb | ethernet | ethercat | profinet | ethernet | ethercat | ethernet |
| interface_specification | Digital I/O | RS422 / RS485 | 4-20mA | Digital I/O | Digital I/O | Digital I/O | 4-20mA | Analog 0-10V |
| Number of measurement channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| source_sampling_rate_basis | DT3060: 200 kSamples/s analog output; 50 kSamples/s digital output; 20 kHz bandwidth | DT3020: 80 kSamples/s analog output; 10 kSamples/s digital output; adjustable bandwidth up to 5 kHz | DT3061: 200 kSamples/s analog output; 50 kSamples/s digital output; 20 kHz bandwidth | DT3061: 200 kSamples/s analog output; 50 kSamples/s digital output; 20 kHz bandwidth | DT3060: 200 kSamples/s analog output; 50 kSamples/s digital output; 20 kHz bandwidth | DT3020: 80 kSamples/s analog output; 10 kSamples/s digital output; adjustable bandwidth up to 5 kHz | DT3020: 80 kSamples/s analog output; 10 kSamples/s digital output; adjustable bandwidth up to 5 kHz | DT3061: 200 kSamples/s analog output; 50 kSamples/s digital output; 20 kHz bandwidth |
| Resolution | 0.04 µm | 0.08 µm | 0.16 µm | 0.04 µm | 0.08 µm | 0.12 µm | 0.24 µm | 0.32 µm |
| Accuracy (% FSO) | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % |
| Start of measuring range | 0.1 mm | 0.2 mm | 0.4 mm | 0.1 mm | 0.2 mm | 0.3 mm | 0.6 mm | 0.8 mm |
| Minimum target diameter | 12 mm | 18 mm | 27 mm | 18 mm | 24 mm | 36 mm | 54 mm | 72 mm |
| Cable length | 3 m | 3 m | 3 m | 3 m | 3 m | 3 m | 3 m | 3 m |
| Operating temperature | -20–200 °C | -20–200 °C | -20–200 °C | -20–180 °C | -20–200 °C | -20–200 °C | -20–200 °C | -20–200 °C |
| End of measuring range | 1.1 mm | 2.2 mm | 4.4 mm | 1.1 mm | 2.2 mm | 3.3 mm | 6.6 mm | 8.800000000000001 mm |
| Accuracy | 1 µm | 2 µm | 4 µm | 1 µm | 2 µm | 3 µm | 6 µm | 8 µm |
| source_sensor_shielding | "shielded" | "shielded" | "shielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" | "unshielded" |
| Working distance | 0.1–1.1 mm | 0.2–2.2 mm | 0.4–4.4 mm | 0.1–1.1 mm | 0.2–2.2 mm | 0.3–3.3 mm | 0.6–6.6 mm | 0.8–8.800000000000001 mm |
| source_sensor_mounting | "Screw connection (M8)" | "Screw connection (M12)" | "Screw connection (M18)" | "Screw connection (M6)" | "Screw connection (M8)" | "Screw connection (M12)" | "Screw connection (M18)" | "Screw connection (M24)" |
| Weight | 0.0024 kg | 0.011 kg | 0.03 kg | 0.0024 kg | 0.0047 kg | 0.012 kg | 0.033 kg | 0.062 kg |
| Storage temperature | -20–200 °C | -20–200 °C | -20–200 °C | -20–180 °C | -20–200 °C | -20–200 °C | -20–200 °C | -20–200 °C |
| Measuring range | 1 mm | 2 mm | 4 mm | 1 mm | 2 mm | 3 mm | 6 mm | 8 mm |
| Linearity | 2 µm | 4 µm | 8 µm | 2 µm | 4 µm | 6 µm | 12 µm | 16 µm |
| source_linearity_basis | Official ES-S1 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-S2 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-S4 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-U1 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-U2 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-U3 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-U6 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. | Official ES-U8 sensor linearity; the DT3020 controller adds <±0.2% FSO after 3-point linearization. |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| ADC sampling rate | 200000 samples/s | 80000 samples/s | 80000 samples/s | 200000 samples/s | 200000 samples/s | 200000 samples/s | 200000 samples/s | 200000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
ES denotes a shielded head. Shielding affects the field and installation requirements; model-specific clearances and specifications still apply.
The principle requires an electrically conductive target. Match calibration to the metal; a steel characteristic does not automatically apply to aluminum.
Use the model’s Start of measuring range. Net span excludes the offset; interval end equals range start plus net span.
Not fully. Table footnotes identify controller, bandwidth and sometimes mid-range position. Check the head/controller combination under the stated conditions.
No. ES-S04, for example, combines front-side pressure resistance with IP50. Pressure, temperature and ingress protection are separate requirements.
Get a quote or advice
Tell us what you need and an engineer will come back to you.