IFS2403
IFS2403: sensors and measurement devices by Micro-Epsilon for distance & displacement sensors.
Visit the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Minimum target thickness | 0.06–1.5 mm |
|---|---|
| Measuring range | 0.4–10 mm |
| Resolution | 0.03–0.46 µm |
| Accuracy | 0.3–8 µm |
| Light spot diameter | 0.009–0.056 mm |
| Start of measuring range | 2.5–14.7 mm |
| Maximum measuring angle | 6–20 deg |
| Number of measurement channels | 1–2 |
| Linearity | 0.12–4 µm |
| ADC sampling rate | 8000–30000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | IFS2403-0.4 eli-m-d9021c0273ae83c1c0322036 | IFS2403-1.5 eli-m-661b6121d7de48f0d3dcbd02 | IFS2403-10 eli-m-8a21db367741cda0ae928c22 | IFS2403-4 eli-m-fab314d1667645370949feb6 | IFS2403/90-1.5 eli-m-6cf59b42ade31923ec91cbeb | IFS2403/90-10 eli-m-c6c18529e4557837402bcf4f | IFS2403/90-4 eli-m-afdfea5d7b84eec14d7bcec3 |
|---|---|---|---|---|---|---|---|
| quantity_specification | 0.4 mm net measuring range | 1.5 mm net measuring range | 10 mm net measuring range | 4 mm net measuring range | 1.5 mm net measuring range | 10 mm net measuring range | 4 mm net measuring range |
| source_linearity_basis | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. |
| Protection class (DIN EN 60529) | ip40 | ip64 | ip40 | ip40 | ip40 | ip64 | ip64 |
| source_target_material | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) |
| source_sampling_rate_basis | IFC2465: 30,000 measurements/s | IFC2421MP: 10,000 measurements/s | IFC2465: 30,000 measurements/s | IFC2416: 25,000 measurements/s | IFC2422: 10,000 measurements/s per synchronous channel | IFC2417: 25,000 measurements/s per synchronous channel | IFC2417: 25,000 measurements/s per synchronous channel |
| interface_specification | 4-20mA | Analog 0-10V | Analog 0-10V | Digital I/O | Analog 0-10V | RS422 / RS485 | Digital I/O |
| Operating temperature | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C |
| Minimum target thickness | 0.06 mm | 0.23 mm | 1.5 mm | 0.6 mm | 0.23 mm | 1.5 mm | 0.6 mm |
| Measuring range | 0.4 mm | 1.5 mm | 10 mm | 4 mm | 1.5 mm | 10 mm | 4 mm |
| Resolution | 0.047 µm | 0.03 µm | 0.125 µm | 0.05 µm | 0.186 µm | 0.125 µm | 0.46 µm |
| Accuracy | 0.3 µm | 1.2 µm | 8 µm | 3 µm | 1.2 µm | 8 µm | 3 µm |
| source_numerical_aperture | 0.5 | 0.3 | 0.15 | 0.15 | 0.3 | 0.15 | 0.15 |
| Light spot diameter | 0.009000000000000001 mm | 0.015 mm | 0.056 mm | 0.028 mm | 0.015 mm | 0.056 mm | 0.028 mm |
| Start of measuring range | 2.5 mm | 8 mm | 11 mm | 14.7 mm | 4.9 mm | 8.6 mm | 12 mm |
| source_mounting_description | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) |
| Weight | 0.2 kg | 0.2 kg | 0.2 kg | 0.2 kg | 0.2 kg | 0.2 kg | 0.2 kg |
| Interfaces | ethercat | ethernet | ethercat | ethernet | ethernet | ethercat | ethercat |
| Maximum measuring angle | 20 deg | 16 deg | 6 deg | 6 deg | 16 deg | 6 deg | 6 deg |
| Number of measurement channels | 1 | 2 | 1 | 2 | 1 | 2 | 2 |
| Linearity | 0.12 µm | 0.45 µm | 4 µm | 1.6 µm | 0.45 µm | 4 µm | 1.6 µm |
| Storage temperature | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| ADC sampling rate | 10000 samples/s | 25000 samples/s | 30000 samples/s | 8000 samples/s | 25000 samples/s | 8000 samples/s | 8000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
They are 8 mm diameter hybrid confocal heads with axial or radial beam paths. The table lists 0.4, 1.5, 4 and 10 mm model-dependent ranges.
No. The maximum angle is a usable-signal limit on reflective surfaces. The footnote states that accuracy decreases towards that limit.
The value is range-specific and refers to glass with refractive index n=1.5 at mid-range. It must not be generalized to every material or position.
The head includes a 2 m fiber and E2000/APC connector. Controller connection and any extension must follow the manufacturer conditions, including bending radius.
It refers to the front of the head, not the entire controller and connection assembly. The head operating temperature is +5 to +70°C.
Get a quote or advice