Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of IFS2407
Number of measurement channels 1–2
Light spot diameter 0.004–0.014 mm
Resolution 0.003–0.075 µm
Measuring range 0.1–6 mm
Weight 0.03–0.8 kg
Start of measuring range 1–32 mm
Linearity 0.04–0.9 µm
Minimum target thickness 0.005–0.3 mm
ADC sampling rate 8000–70000 samples/s
Accuracy 0.04–0.9 µm

Models in the series

One column per model: what differs between the models of the series.

Models of IFS2407 compared by parameter
Parameter IFS2407-0.1 eli-m-5e1d52b6b70af4ae362b2e43 IFS2407-0.1(001) eli-m-d2eb89605555f2f3330520fe IFS2407-0.8 eli-m-28d0345ec7edfe8ede4234da IFS2407-1.5 eli-m-b18d4bb8bbc40e3307f3b35e IFS2407-3 eli-m-098d1bd05a548c597edb9043 IFS2407-6 eli-m-f3da3a0883db21d05ed16793 IFS2407/90-0.3 eli-m-a94cd2b95e9836c8114b52c2
Protection class (DIN EN 60529) ip40 ip64 ip40 ip65 ip64 ip40 ip40
Number of measurement channels 2 Not specified 2 1 1 2 2
Interfaces ethercat ethercat ethercat ethercat ethercat ethernet ethercat
interface_specification Digital I/O Not specified RS422 / RS485 4-20mA Digital I/O Digital I/O Digital I/O
source_sampling_rate_basis IFC2466: 30,000 measurements/s per synchronous channel Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. IFC2411: 8,000 measurements/s IFC2416: 25,000 measurements/s IFC2465MP: 30,000 measurements/s IFC2465: 30,000 measurements/s IFC2416: 25,000 measurements/s
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
source_target_material reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass)
source_mounting_description Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Mounting holes (2x M2)
Operating temperature 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C
Light spot diameter 0.004 mm 0.004 mm 0.006 mm 0.0055 mm 0.009000000000000001 mm 0.014 mm 0.006 mm
Resolution 0.006 µm 0.006 µm 0.075 µm 0.003 µm 0.007 µm 0.008 µm 0.02 µm
Measuring range 0.1 mm 0.1 mm 0.8 mm 1.5 mm 3 mm 6 mm 0.3 mm
Weight 0.036 kg 0.036 kg 0.04 kg 0.8 kg 0.55 kg 0.35 kg 0.03 kg
Start of measuring range 1 mm 1 mm 5.9 mm 17 mm 28 mm 32 mm 5.3 mm
Linearity 0.04 µm Not specified 0.2 µm 0.16 µm 0.45 µm 0.9 µm 0.1 µm
quantity_specification 0.1 mm net measuring range 0-0.1 mm mapped range. Official confocalDT sensor range. 0.8 mm net measuring range 1.5 mm net measuring range 3 mm net measuring range 6 mm net measuring range 0.3 mm net measuring range
Minimum target thickness 0.005 mm 0.005 mm 0.04 mm 0.075 mm 0.15 mm 0.3 mm 0.015 mm
source_linearity_basis https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity.
source_special_features Sensor with high numerical aperture Light-intensive sensor Not specified Not specified Not specified Not specified Not specified
source_numerical_aperture 0.8 0.7 0.5 0.7 0.53 0.45 0.5
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 8000 samples/s 70000 samples/s 10000 samples/s 8000 samples/s 25000 samples/s 30000 samples/s 10000 samples/s
Accuracy 0.04 µm 0.04 µm 0.2 µm 0.3 µm 0.45 µm 0.9 µm 0.1 µm
source_sampling_rate_limited_by_readout Not specified True Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a high-precision confocal-head family with separate models spanning 0.1 to 6 mm. Light-spot diameter, linearity and measuring angle vary by model.

No. It is a footnoted value for IFS2407-1.5 on diffusely reflecting metallic surfaces. Its other specified angle is ±43°, and accuracy decreases towards the limits.

No. The 0.1 mm model columns have no thickness-linearity value. Do not substitute distance linearity or assign unsupported thickness performance.

Add a compatible fiber for the FC socket and a confocalDT controller. Evaluate rate and resolution for the combination and operating conditions, including any specified averaging.

No. The standard table specifies +5 to +70°C. A 200°C environment requires the dedicated HT/VAC family and its own specifications and accessories.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words