| Number of measurement channels | 1–2 |
|---|---|
| Light spot diameter | 0.004–0.014 mm |
| Resolution | 0.003–0.075 µm |
| Measuring range | 0.1–6 mm |
| Weight | 0.03–0.8 kg |
| Start of measuring range | 1–32 mm |
| Linearity | 0.04–0.9 µm |
| Minimum target thickness | 0.005–0.3 mm |
| ADC sampling rate | 8000–70000 samples/s |
| Accuracy | 0.04–0.9 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | IFS2407-0.1 eli-m-5e1d52b6b70af4ae362b2e43 | IFS2407-0.1(001) eli-m-d2eb89605555f2f3330520fe | IFS2407-0.8 eli-m-28d0345ec7edfe8ede4234da | IFS2407-1.5 eli-m-b18d4bb8bbc40e3307f3b35e | IFS2407-3 eli-m-098d1bd05a548c597edb9043 | IFS2407-6 eli-m-f3da3a0883db21d05ed16793 | IFS2407/90-0.3 eli-m-a94cd2b95e9836c8114b52c2 |
|---|---|---|---|---|---|---|---|
| Protection class (DIN EN 60529) | ip40 | ip64 | ip40 | ip65 | ip64 | ip40 | ip40 |
| Number of measurement channels | 2 | Not specified | 2 | 1 | 1 | 2 | 2 |
| Interfaces | ethercat | ethercat | ethercat | ethercat | ethercat | ethernet | ethercat |
| interface_specification | Digital I/O | Not specified | RS422 / RS485 | 4-20mA | Digital I/O | Digital I/O | Digital I/O |
| source_sampling_rate_basis | IFC2466: 30,000 measurements/s per synchronous channel | Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. | IFC2411: 8,000 measurements/s | IFC2416: 25,000 measurements/s | IFC2465MP: 30,000 measurements/s | IFC2465: 30,000 measurements/s | IFC2416: 25,000 measurements/s |
| Storage temperature | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| source_target_material | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) | reflective, diffuse as well as transparent surfaces (e.g. glass) |
| source_mounting_description | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Radial clamping (mounting adapter see accessories) | Mounting holes (2x M2) |
| Operating temperature | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C | 5–70 °C |
| Light spot diameter | 0.004 mm | 0.004 mm | 0.006 mm | 0.0055 mm | 0.009000000000000001 mm | 0.014 mm | 0.006 mm |
| Resolution | 0.006 µm | 0.006 µm | 0.075 µm | 0.003 µm | 0.007 µm | 0.008 µm | 0.02 µm |
| Measuring range | 0.1 mm | 0.1 mm | 0.8 mm | 1.5 mm | 3 mm | 6 mm | 0.3 mm |
| Weight | 0.036 kg | 0.036 kg | 0.04 kg | 0.8 kg | 0.55 kg | 0.35 kg | 0.03 kg |
| Start of measuring range | 1 mm | 1 mm | 5.9 mm | 17 mm | 28 mm | 32 mm | 5.3 mm |
| Linearity | 0.04 µm | Not specified | 0.2 µm | 0.16 µm | 0.45 µm | 0.9 µm | 0.1 µm |
| quantity_specification | 0.1 mm net measuring range | 0-0.1 mm mapped range. Official confocalDT sensor range. | 0.8 mm net measuring range | 1.5 mm net measuring range | 3 mm net measuring range | 6 mm net measuring range | 0.3 mm net measuring range |
| Minimum target thickness | 0.005 mm | 0.005 mm | 0.04 mm | 0.075 mm | 0.15 mm | 0.3 mm | 0.015 mm |
| source_linearity_basis | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | Stored as the conservative published family/model accuracy for catalog filtering. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. | https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. |
| source_special_features | Sensor with high numerical aperture | Light-intensive sensor | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_numerical_aperture | 0.8 | 0.7 | 0.5 | 0.7 | 0.53 | 0.45 | 0.5 |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| ADC sampling rate | 8000 samples/s | 70000 samples/s | 10000 samples/s | 8000 samples/s | 25000 samples/s | 30000 samples/s | 10000 samples/s |
| Accuracy | 0.04 µm | 0.04 µm | 0.2 µm | 0.3 µm | 0.45 µm | 0.9 µm | 0.1 µm |
| source_sampling_rate_limited_by_readout | Not specified | True | Not specified | Not specified | Not specified | Not specified | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is a high-precision confocal-head family with separate models spanning 0.1 to 6 mm. Light-spot diameter, linearity and measuring angle vary by model.
No. It is a footnoted value for IFS2407-1.5 on diffusely reflecting metallic surfaces. Its other specified angle is ±43°, and accuracy decreases towards the limits.
No. The 0.1 mm model columns have no thickness-linearity value. Do not substitute distance linearity or assign unsupported thickness performance.
Add a compatible fiber for the FC socket and a confocalDT controller. Evaluate rate and resolution for the combination and operating conditions, including any specified averaging.
No. The standard table specifies +5 to +70°C. A 200°C environment requires the dedicated HT/VAC family and its own specifications and accessories.
Get a quote or advice
Tell us what you need and an engineer will come back to you.