Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of induSENSOR DTA gauge
Number of measurement channels 1–2
Accuracy 6–60 µm
Repeatability 0.15–1.5 µm

Models in the series

One column per model: what differs between the models of the series.

Models of induSENSOR DTA gauge compared by parameter
Parameter DTA-10G8-3-CA eli-m-bb1767b1beb66cdd39efca8d DTA-10G8-3-CA-V eli-m-b23764803e5c8d6ac28bdb5c DTA-1G8-3-CA eli-m-4c2e33e88e97db9b910cd594 DTA-1G8-3-CA-V eli-m-1a46aade1233e44deef2c063 DTA-3G8-3-CA eli-m-0de1c35f09e22ca72762ecab DTA-3G8-3-CA-V eli-m-9fce58536531ae63071e35c7 DTA-5G8-3-CA eli-m-a3f501d12eb7bba0d09a1e6f DTA-5G8-3-CA-V eli-m-49dfa721793ba916012257d0
interface_specification Analog 0-10V Analog 0-10V RS422 / RS485 4-20mA 4-20mA Analog 0-10V RS422 / RS485 RS422 / RS485
Number of measurement channels 2 2 2 2 2 2 2 1
source_repeatability_basis Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values.
Accuracy 60 µm 60 µm 6 µm 6 µm 18 µm 18 µm 30 µm 30 µm
quantity_specification 0-20 mm model-level measuring interval 0-20 mm model-level measuring interval 0-2 mm model-level measuring interval 0-2 mm model-level measuring interval 0-6 mm model-level measuring interval 0-6 mm model-level measuring interval 0-10 mm model-level measuring interval 0-10 mm model-level measuring interval
source_linearity_basis Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code.
Interfaces ethercat ethernet ethercat ethercat profinet ethernet ethernet profinet
Repeatability 1.5 µm 1.5 µm 0.15 µm 0.15 µm 0.45 µm 0.45 µm 0.75 µm 0.75 µm
source_sampling_rate_basis MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ.
Contact Contact Contact Contact Contact Contact Contact Contact Contact
ADC sampling rate 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s
Status Active Active Active Active Active Active Active Active
Datasheet PDF — DTA-10G8-3-CA (opens in a new tab) PDF — DTA-10G8-3-CA-V (opens in a new tab) PDF — DTA-1G8-3-CA (opens in a new tab) PDF — DTA-1G8-3-CA-V (opens in a new tab) PDF — DTA-3G8-3-CA (opens in a new tab) PDF — DTA-3G8-3-CA-V (opens in a new tab) PDF — DTA-5G8-3-CA (opens in a new tab) PDF — DTA-5G8-3-CA-V (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Contact dimensional measurement such as height, thickness and diameter. Spring-return and pneumatic versions are available; choose a probe tip for the surface.

No. Its range is ±5 mm around zero, giving a 10 mm total measuring span. A bipolar designation is not the net span.

No. That value requires a linearized controller as a system service and consideration of the installation. Distinguish it from standard linearity.

MSC7401, MSC7802 and MSC7602 are listed. Their selection determines channel count, connections and measurement-chain performance.

No. The table specifies IP65 with bellows and IP54 without. Operating temperature and spring forces also depend on configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words