induSENSOR DTA gauge LVDT
induSENSOR DTA gauge: sensors and measurement devices by Micro-Epsilon for lvdt.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Number of measurement channels | 1–2 |
|---|---|
| Accuracy | 6–60 µm |
| Repeatability | 0.15–1.5 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DTA-10G8-3-CA eli-m-bb1767b1beb66cdd39efca8d | DTA-10G8-3-CA-V eli-m-b23764803e5c8d6ac28bdb5c | DTA-1G8-3-CA eli-m-4c2e33e88e97db9b910cd594 | DTA-1G8-3-CA-V eli-m-1a46aade1233e44deef2c063 | DTA-3G8-3-CA eli-m-0de1c35f09e22ca72762ecab | DTA-3G8-3-CA-V eli-m-9fce58536531ae63071e35c7 | DTA-5G8-3-CA eli-m-a3f501d12eb7bba0d09a1e6f | DTA-5G8-3-CA-V eli-m-49dfa721793ba916012257d0 |
|---|---|---|---|---|---|---|---|---|
| interface_specification | Analog 0-10V | Analog 0-10V | RS422 / RS485 | 4-20mA | 4-20mA | Analog 0-10V | RS422 / RS485 | RS422 / RS485 |
| Number of measurement channels | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1 |
| source_repeatability_basis | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. | Official Micro-Epsilon DTA-xG8 data: repeatability, 200 repetitions with each repetition averaged over 100 values. |
| Accuracy | 60 µm | 60 µm | 6 µm | 6 µm | 18 µm | 18 µm | 30 µm | 30 µm |
| quantity_specification | 0-20 mm model-level measuring interval | 0-20 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-2 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-6 mm model-level measuring interval | 0-10 mm model-level measuring interval | 0-10 mm model-level measuring interval |
| source_linearity_basis | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. | Official Micro-Epsilon DTA-xG8 data: independent linearity, ±0.3 % FSO for the exact ordering code. |
| Interfaces | ethercat | ethernet | ethercat | ethercat | profinet | ethernet | ethernet | profinet |
| Repeatability | 1.5 µm | 1.5 µm | 0.15 µm | 0.15 µm | 0.45 µm | 0.45 µm | 0.75 µm | 0.75 µm |
| source_sampling_rate_basis | MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7602: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. |
| Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact | Contact |
| ADC sampling rate | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — DTA-10G8-3-CA (opens in a new tab) | PDF — DTA-10G8-3-CA-V (opens in a new tab) | PDF — DTA-1G8-3-CA (opens in a new tab) | PDF — DTA-1G8-3-CA-V (opens in a new tab) | PDF — DTA-3G8-3-CA (opens in a new tab) | PDF — DTA-3G8-3-CA-V (opens in a new tab) | PDF — DTA-5G8-3-CA (opens in a new tab) | PDF — DTA-5G8-3-CA-V (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Contact dimensional measurement such as height, thickness and diameter. Spring-return and pneumatic versions are available; choose a probe tip for the surface.
No. Its range is ±5 mm around zero, giving a 10 mm total measuring span. A bipolar designation is not the net span.
No. That value requires a linearized controller as a system service and consideration of the installation. Distinguish it from standard linearity.
MSC7401, MSC7802 and MSC7602 are listed. Their selection determines channel count, connections and measurement-chain performance.
No. The table specifies IP65 with bellows and IP54 without. Operating temperature and spring forces also depend on configuration.
Get a quote or advice
Tell us what you need and an engineer will come back to you.