induSENSOR LDR LVDT
induSENSOR LDR: sensors and measurement devices by Micro-Epsilon for lvdt.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Accuracy | 20–100 µm |
|---|---|
| Number of measurement channels | 1–2 |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | LDR-10-CA eli-m-7c3e8c489aef3e3edc0620bc | LDR-10-SA eli-m-b1153f904ddb5577ed654727 | LDR-25-CA eli-m-35d621c1e4e19aa02aa4d22f | LDR-25-SA eli-m-8f6dfa749852a0d44fb26aa8 | LDR-50-CA eli-m-6dd5b638030ee2380f708d88 | LDR-50-SA eli-m-fa3600fe42b3723c33e91e74 |
|---|---|---|---|---|---|---|
| interface_specification | Analog 0-10V | RS422 / RS485 | 4-20mA | Analog 0-10V | 4-20mA | RS422 / RS485 |
| source_sampling_rate_basis | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7401: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. | MSC7802: documented induSENSOR controller configuration; verify the selected excitation frequency, output bandwidth and interface module at RFQ. |
| quantity_specification | 0-10 mm model-level measuring interval | 0-10 mm model-level measuring interval | 0-25 mm model-level measuring interval | 0-25 mm model-level measuring interval | 0-50 mm model-level measuring interval | 0-50 mm model-level measuring interval |
| Accuracy | 20 µm | 20 µm | 50 µm | 50 µm | 100 µm | 100 µm |
| Number of measurement channels | 1 | 2 | 2 | 2 | 2 | 1 |
| Interfaces | ethercat | ethernet | ethernet | ethernet | ethernet | ethernet |
| source_linearity_basis | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. | Official Micro-Epsilon induSENSOR LDR catalog data: the retained value is model-level linearity, not an inferred repeatability value. |
| Contact | Contact | Contact | Contact | Contact | Contact | Contact |
| ADC sampling rate | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s | 5000 samples/s |
| Status | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — LDR-10-CA (opens in a new tab) | PDF — LDR-10-SA (opens in a new tab) | PDF — LDR-25-CA (opens in a new tab) | PDF — LDR-25-SA (opens in a new tab) | PDF — LDR-50-CA (opens in a new tab) | PDF — LDR-50-SA (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is an inductive half-bridge sensor with a short housing and moving plunger. It needs compatible excitation/controller, not direct treatment as a standalone 0–10 V sensor.
Not in the standard table. CA integral-cable versions are rated to 160°C; SA connector versions to 80°C.
No. The linearized row requires a linearized controller as a system service and consideration of installation conditions. It differs from the standard row.
Half-bridge operation, excitation frequency/voltage, range, bandwidth and output. Listed excitation frequency varies by model and is not the sampling rate.
The table specifies a 2 m integral cable and 10 mm minimum bend radius for fixed installation. This does not establish suitability for every repeated-motion application.