optoNCDT 1220 Laser triangulation
optoNCDT 1220: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| repeatability_length | 1–50 µm |
|---|---|
| rate_option | 250–2000 Hz |
| distance_start | 20–100 mm |
| Working distance | 20–600 mm |
| distance_end | 30–600 mm |
| linearity_length | 10–1500 µm |
| distance_net_span | 10–500 mm |
| Light spot width Y | 0.05–0.91 mm |
| Light spot width X | 0.045–0.71 mm |
| Accuracy | 10–1500 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ILD1220-10 eli-m-451d6d5fe67f89e5a62a1c40 | ILD1220-10-IO-Link eli-m-30bc9e23e55ffa0bd941599a | ILD1220-100 eli-m-cfcd095c94505433f94924b7 | ILD1220-100-IO-Link eli-m-9fac25fb6d7191e90f4fbb16 | ILD1220-200 eli-m-e1fceb8ce9b3b3391e3366d9 | ILD1220-200-IO-Link eli-m-b9cd4c91203b4e3781b0cdd8 | ILD1220-25 eli-m-ebc112b67019357ae2cc472e | ILD1220-25-IO-Link eli-m-bd9bf2bc1cdcad15c1fe5382 | ILD1220-50 eli-m-5dd70279889c9eb3f9220db1 | ILD1220-50-IO-Link eli-m-b69288ce239bc5ee01ecca1f | ILD1220-500 eli-m-2e47797290b88f6618103eb2 | ILD1220-500-IO-Link eli-m-fe6092f1a9de85c0399965c2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| repeatability_length | 1 µm | 1 µm | 10 µm | 10 µm | 20 µm | 20 µm | 2.5 µm | 2.5 µm | 5 µm | 5 µm | 50 µm | 50 µm |
| rate_option | 1000 Hz | Not specified | 500 Hz | Not specified | 2000 Hz | Not specified | 250 Hz | Not specified | 500 Hz | Not specified | 1000 Hz | Not specified |
| native_interfaces | rs422 | io_link | rs422 | io_link | rs422 | io_link | rs422 | io_link | rs422 | io_link | rs422 | io_link |
| interface_specification | RS422 / RS485 | Not specified | Analog 0-10V | Not specified | 4-20mA | Not specified | RS422 / RS485 | Not specified | 4-20mA | Not specified | RS422 / RS485 | Not specified |
| distance_start | 20 mm | 20 mm | 50 mm | 50 mm | 60 mm | 60 mm | 25 mm | 25 mm | 35 mm | 35 mm | 100 mm | 100 mm |
| Operating temperature | 0–50 °C | Not specified | 0–50 °C | Not specified | 0–50 °C | Not specified | 0–50 °C | Not specified | 0–50 °C | Not specified | 0–50 °C | Not specified |
| Working distance | 20–30 mm | Not specified | 50–150 mm | Not specified | 60–260 mm | Not specified | 25–50 mm | Not specified | 35–85 mm | Not specified | 100–600 mm | Not specified |
| distance_end | 30 mm | 30 mm | 150 mm | 150 mm | 260 mm | 260 mm | 50 mm | 50 mm | 85 mm | 85 mm | 600 mm | 600 mm |
| ip_rating | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| linearity_length | 10 µm | 10 µm | 100 µm | 100 µm | 200 µm | 200 µm | 25 µm | 25 µm | 50 µm | 50 µm | Not specified | < ±750…1500 µm |
| quantity_specification | 10 mm net measuring range; 20-30 mm sensor-to-target working window. | Not specified | 100 mm net measuring range; 50-150 mm sensor-to-target working window. | Not specified | 200 mm net measuring range; 60-260 mm sensor-to-target working window. | Not specified | 25 mm net measuring range; 25-50 mm sensor-to-target working window. | Not specified | Not specified | Not specified | 500 mm net measuring range; 100-600 mm sensor-to-target working window. | Not specified |
| measurement_rate | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz | 2000 Hz |
| distance_net_span | 10 mm | 10 mm | 100 mm | 100 mm | 200 mm | 200 mm | 25 mm | 25 mm | 50 mm | 50 mm | 500 mm | 500 mm |
| measurement_rate_factory | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz | 1000 Hz |
| contact_type | Non-contact | non-contact | Non-contact | non-contact | Non-contact | non-contact | Non-contact | non-contact | Non-contact | non-contact | Non-contact | non-contact |
| Light spot size on target at mid measuring range | 45 × 50 µm | 45 × 50 µm (MMR) | Not specified | 750 × 1100 µm (MMR) | Not specified | 750 × 1100 µm (MMR) | Not specified | 55 × 60 µm (MMR) | Not specified | 80 × 95 µm (MMR) | Not specified | 750 × 1100 µm (MMR) |
| Light spot width Y | 0.05 mm | Not specified | 0.91 mm | Not specified | 0.91 mm | Not specified | 0.33 mm | Not specified | 0.095 mm | Not specified | 0.91 mm | Not specified |
| Light spot width X | 0.045 mm | Not specified | 0.71 mm | Not specified | 0.71 mm | Not specified | 0.255 mm | Not specified | 0.25 mm | Not specified | 0.71 mm | Not specified |
| Accuracy | 10 µm | Not specified | 100 µm | Not specified | 200 µm | Not specified | 25 µm | Not specified | 50 µm | Not specified | 1500 µm | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — ILD1220-10 (opens in a new tab) | PDF — ILD1220-10-IO-Link (opens in a new tab) | PDF — ILD1220-100 (opens in a new tab) | PDF — ILD1220-100-IO-Link (opens in a new tab) | PDF — ILD1220-200 (opens in a new tab) | PDF — ILD1220-200-IO-Link (opens in a new tab) | PDF — ILD1220-25 (opens in a new tab) | PDF — ILD1220-25-IO-Link (opens in a new tab) | PDF — ILD1220-50 (opens in a new tab) | PDF — ILD1220-50-IO-Link (opens in a new tab) | PDF — ILD1220-500 (opens in a new tab) | PDF — ILD1220-500-IO-Link (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Micro-Epsilon specifies a configurable measuring rate up to 2 kHz. Distinguish that capability from the selected operating setting and the data-transfer rate of the complete system.
Its measuring controller is integrated into the sensor. Connection to plant automation can require an interface adapter or IO-Link master according to the sensor version and required interface; these serve a different role from an external measuring controller.
No. Its net span is 10 mm, but the interval is 20–30 mm from the sensor. Match both working interval and installation distance.
The catalogue footnote specifies 1 kHz and median 9. Preserve these conditions and distinguish repeatability from linearity.
Use both dimensions together and state their range position. ILD1220-10 specifies 45×50 µm at mid-range, with different sizes at the start and end.
Get a quote or advice
Tell us what you need and an engineer will come back to you.