optoNCDT 1320 Laser triangulation
optoNCDT 1320: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Linearity | 10–200 µm |
|---|---|
| Repeatability | 1–50 µm |
| Start of measuring range | 20–100 mm |
| End of measuring range | 30–600 mm |
| rate_option | 250–4000 Hz |
| Measuring range | 10–500 mm |
| Light spot width X | 0.045–0.71 mm |
| Light spot width Y | 0.05–0.91 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ILD1320-10 eli-m-7651abb303d2baa394dde6dd | ILD1320-100 eli-m-897b4d8c921f36ceacf2307a | ILD1320-200 eli-m-df8861412924623cb22295d7 | ILD1320-25 eli-m-9d837eff40485c6d72fd44c9 | ILD1320-50 eli-m-6a8aa8b80ddfd4c5462729c2 | ILD1320-500 eli-m-bd0f49ecec68c344fc3ba548 |
|---|---|---|---|---|---|---|
| Resolution | 1 µm | 1 µm | 1 µm | 1 µm | 1 µm | 1 µm |
| Linearity | 10 µm | 100 µm | 200 µm | 25 µm | 50 µm | Not specified |
| Repeatability | 1 µm | 10 µm | 20 µm | 2.5 µm | 5 µm | 50 µm |
| Operating temperature | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C |
| Start of measuring range | 20 mm | 50 mm | 60 mm | 25 mm | 35 mm | 100 mm |
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| Interfaces | profinet | ethernet | rs422 | profinet | ethernet | profinet |
| End of measuring range | 30 mm | 150 mm | 260 mm | 50 mm | 85 mm | 600 mm |
| rate_option | 4000 Hz | 4000 Hz | 250 Hz | 250 Hz | 1000 Hz | 250 Hz |
| Measuring range | 10 mm | 100 mm | 200 mm | 25 mm | 50 mm | 500 mm |
| Measuring rate | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz |
| interface_specification | Analog 0-10V | Analog 0-10V | Analog 0-10V | Analog 0-10V | RS422 / RS485 | Analog 0-10V |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| Light spot size at mid of measuring range | 45 × 50 µm | 710 × 910 µm | 710 × 910 µm | 55 × 60 µm | Not specified | Not specified |
| Light spot width X | 0.045 mm | 0.71 mm | 0.71 mm | 0.055 mm | 0.07000000000000001 mm | 0.71 mm |
| Light spot width Y | 0.05 mm | 0.91 mm | 0.91 mm | 0.06 mm | 0.095 mm | 0.91 mm |
| ADC sampling rate | 4000 samples/s | 4000 samples/s | 4000 samples/s | 4000 samples/s | 4000 samples/s | 4000 samples/s |
| Status | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — ILD1320-10 (opens in a new tab) | PDF — ILD1320-100 (opens in a new tab) | PDF — ILD1320-200 (opens in a new tab) | PDF — ILD1320-25 (opens in a new tab) | PDF — ILD1320-50 (opens in a new tab) | PDF — ILD1320-500 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Its measurement electronics are integrated into the sensor housing. Connection components are selected separately for the interface and configuration.
No. Micro-Epsilon lists them separately. Compare the relevant specification for the selected model without substituting repeatability for linearity.
The catalogue specifies up to 4 kHz versus a 1 kHz factory setting. Changing it requires the stated setup tools/interface, including IF2001/USB.
No. Dimensions vary by model span and start/mid/end position. Read both dimensions as one spot specification with its measurement position.
No. The 500 mm model has a separate linearity specification. Use its model column and preserve the manufacturer’s white diffuse target conditions.
Get a quote or advice
Tell us what you need and an engineer will come back to you.