optoNCDT 1760-1000 Laser triangulation
optoNCDT 1760-1000: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ILD1760-1000 eli-m-0f3fd27d0c4ea7cd5c2e2001 |
|---|---|
| Interfaces | ethercat |
| Working distance | 1000–2000 mm |
| Operating temperature | 0–50 °C |
| Start of measuring range | 1000 mm |
| quantity_specification | Measuring range 1000 mm; start/midpoint/end 1000/1500/2000 mm. Ambient-light tolerance 10,000 lx. Sensor mass about 800 g. |
| End of measuring range | 2000 mm |
| Protection class (DIN EN 60529) | ip65 |
| Measuring range | 1000 mm |
| Repeatability | 100 µm |
| interface_specification | RS422 / RS485 |
| Measuring rate | 7500 Hz |
| source_linearity_basis | Official maximum linearity deviation ±1000 µm, equivalent to ±0.1% FSO. |
| Linearity | 1000 µm |
| source_sampling_rate_basis | Selectable 7.5, 5, 2.5, 1.25 kHz, 625 Hz and 300 Hz; repeatability is specified at 5 kHz with median 9. |
| source_repeatability_basis | Official repeatability 100 µm at 5 kHz with median 9. |
| Accuracy (% FSO) | 0.1 % |
| Contact | Non-contact |
| Accuracy | 1000 µm |
| ADC sampling rate | 7500 samples/s |
| Status | Active |
| Datasheet | PDF — ILD1760-1000 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. Its net span is 1000 mm and working interval is 1000–2000 mm from the sensor, with a 1500 mm midpoint.
The table specifies up to 7.5 kHz and a 5 kHz factory setting. Changes require the setup path stated in the instructions.
No. It refers to 0.1% FSO of its 1000 mm span, equivalent to 1 mm. Repeatability is separately specified under stated test conditions.
The table lists a light-spot size on the order of 2.5–5 mm. Check that target and measured feature suit the spot at the working distance.
It specifies a 0.25 m pigtail with a 14-pin ODU connector. Select a matching cable; the listed Industrial Ethernet interfaces require an appropriate module.
Get a quote or advice
Tell us what you need and an engineer will come back to you.