Skip to content

optoNCDT 1760-1000 Laser triangulation

optoNCDT 1760-1000: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT 1760-1000 compared by parameter
Parameter ILD1760-1000 eli-m-0f3fd27d0c4ea7cd5c2e2001
Interfaces ethercat
Working distance 1000–2000 mm
Operating temperature 0–50 °C
Start of measuring range 1000 mm
quantity_specification Measuring range 1000 mm; start/midpoint/end 1000/1500/2000 mm. Ambient-light tolerance 10,000 lx. Sensor mass about 800 g.
End of measuring range 2000 mm
Protection class (DIN EN 60529) ip65
Measuring range 1000 mm
Repeatability 100 µm
interface_specification RS422 / RS485
Measuring rate 7500 Hz
source_linearity_basis Official maximum linearity deviation ±1000 µm, equivalent to ±0.1% FSO.
Linearity 1000 µm
source_sampling_rate_basis Selectable 7.5, 5, 2.5, 1.25 kHz, 625 Hz and 300 Hz; repeatability is specified at 5 kHz with median 9.
source_repeatability_basis Official repeatability 100 µm at 5 kHz with median 9.
Accuracy (% FSO) 0.1 %
Contact Non-contact
Accuracy 1000 µm
ADC sampling rate 7500 samples/s
Status Active
Datasheet PDF — ILD1760-1000 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. Its net span is 1000 mm and working interval is 1000–2000 mm from the sensor, with a 1500 mm midpoint.

The table specifies up to 7.5 kHz and a 5 kHz factory setting. Changes require the setup path stated in the instructions.

No. It refers to 0.1% FSO of its 1000 mm span, equivalent to 1 mm. Repeatability is separately specified under stated test conditions.

The table lists a light-spot size on the order of 2.5–5 mm. Check that target and measured feature suit the spot at the working distance.

It specifies a 0.25 m pigtail with a 14-pin ODU connector. Select a matching cable; the listed Industrial Ethernet interfaces require an appropriate module.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words