ILD1910-750
From the optoNCDT 1910 series
optoNCDT 1910: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 750 mm |
|---|---|
| Start of measuring range | 200 mm |
| End of measuring range | 950 mm |
| Working distance | 200–950 mm |
| Linearity (% FSO) | 0.08 % |
| Repeatability | 30 µm |
| Measuring rate | 9500 Hz |
| Interfaces | profinet |
| interface_specification | 4-20mA |
| Operating temperature | 0–50 °C |
| Protection class (DIN EN 60529) | ip67 |
| quantity_specification | Measuring range 750 mm; start/midpoint/end 200/575/950 mm. Ambient-light tolerance 10,000 lx. Sensor mass about 600 g. |
| Accuracy | 600 µm |
| Accuracy (% FSO) | 0.08 % |
| source_linearity_basis | Official maximum linearity deviation ±600 µm, equivalent to ±0.08% FSO. |
| Light spot width X | 1.1 mm |
| source_sampling_rate_basis | Continuously adjustable 0.25-9.5 kHz; fixed stages 9.5, 8, 4, 2, 1 kHz, 500 Hz and 250 Hz. |
| Interfaces | rs422 |
| interface_specification | RS422 / RS485 |
| interface_specification | Digital I/O |
| interface_specification | Analog 0-10V |
| Interfaces | ethernet_ip |
| Light spot width Y | 1.1 mm |
| source_repeatability_basis | Official repeatability 30 µm under datasheet reference conditions. |
| Interfaces | ethercat |
| Interfaces | ethernet |
| Contact | Non-contact |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.