Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring window | 24–500 mm |
|---|---|
| Light spot width Y | 0.07–0.38 mm |
| Light spot width X | 0.03–0.38 mm |
| Measuring rate | 20000–49140 Hz |
| rate_option | 1500–49140 Hz |
| Measuring range | 2–300 mm |
| Working distance | 24–500 mm |
| Resolution | 0.03–4.5 µm |
| Linearity | 0.6–90 µm |
| Accuracy | 0.6–90 µm |
| Light spot diameter | 0.13–1.3 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ILD2300-10 eli-m-6a538433cb54bcfa4486e942 | ILD2300-100 eli-m-11f5ea4909d939f1e2ce5b0f | ILD2300-2 eli-m-dfffe354a94ee7173e18e707 | ILD2300-20 eli-m-004914d0cc32515f361c90c0 | ILD2300-200 eli-m-6f158e04ef7f13f957a2cc60 | ILD2300-300 eli-m-c181774b9b329b6d6da0bf07 | ILD2300-5 eli-m-3d2df53c0ba4585af90a7ea5 | ILD2300-50 eli-m-d77dff06a3e04f6ba7d031ce |
|---|---|---|---|---|---|---|---|---|
| Measuring window | 30–40 mm | 70–170 mm | 24–26 mm | 40–60 mm | 130–330 mm | 200–500 mm | 24–26 mm | 45–95 mm |
| Light spot width Y | 0.16 mm | Not specified | 0.08500000000000001 mm | 0.2 mm | Not specified | 0.38 mm | 0.08 mm | 0.07000000000000001 mm |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Analog 0-10V | Analog 0-10V | Analog 0-10V | Digital I/O | Digital I/O |
| Protection class (DIN EN 60529) | ip65 | ip65 | ip65 | ip65 | ip65 | ip65 | ip65 | ip65 |
| Light spot width X | 0.11 mm | Not specified | 0.055 mm | 0.14 mm | Not specified | 0.38 mm | 0.03 mm | 0.255 mm |
| Measuring rate | 49140 Hz | 20000 Hz | 20000 Hz | 49140 Hz | 49140 Hz | 49140 Hz | 49140 Hz | 49140 Hz |
| Interfaces | ethercat | ethercat | ethernet | ethercat | ethernet | ethercat | ethercat | ethernet |
| rate_option | 49140 Hz | 30000 Hz | 30000 Hz | 30000 Hz | 1500 Hz | 49140 Hz | 30000 Hz | 10000 Hz |
| Operating temperature | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C |
| Measuring range | 10 mm | 100 mm | 2 mm | 10 mm | 200 mm | 300 mm | 2 mm | 50 mm |
| Working distance | 30–40 mm | 70–170 mm | 24–26 mm | 40–60 mm | 120–420 mm | 200–500 mm | 24–29 mm | 45–95 mm |
| Resolution | 0.15 µm | 1.5 µm | 0.03 µm | 0.3 µm | 3 µm | 4.5 µm | 0.08 µm | 0.8 µm |
| quantity_specification | 10 mm net measuring range; 30-40 mm sensor-to-target working window. | 100 mm net measuring range; 70-170 mm sensor-to-target working window. | 2 mm net measuring range; 24-26 mm sensor-to-target working window. | 20 mm net measuring range; 40-60 mm sensor-to-target working window. | Not specified | 300 mm net measuring range; 200-500 mm sensor-to-target working window. | 5 mm net measuring range; 24-29 mm sensor-to-target working window. | 50 mm net measuring range; 45-95 mm sensor-to-target working window. |
| Linearity | 2 µm | 20 µm | 0.6 µm | 4 µm | 60 µm | 90 µm | 1.5 µm | 10 µm |
| Storage temperature | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| Accuracy | 2 µm | 20 µm | 0.6 µm | 4 µm | 60 µm | 90 µm | 1.5 µm | 10 µm |
| ADC sampling rate | 30000 samples/s | 30000 samples/s | 30000 samples/s | 30000 samples/s | 30000 samples/s | 30000 samples/s | 30000 samples/s | 30000 samples/s |
| Light spot diameter | Not specified | 0.13 mm | Not specified | Not specified | 1.3 mm | Not specified | Not specified | Not specified |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — ILD2300-10 (opens in a new tab) | PDF — ILD2300-100 (opens in a new tab) | PDF — ILD2300-2 (opens in a new tab) | PDF — ILD2300-20 (opens in a new tab) | PDF — ILD2300-200 (opens in a new tab) | PDF — ILD2300-300 (opens in a new tab) | PDF — ILD2300-5 (opens in a new tab) | PDF — ILD2300-50 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Not necessarily. The manufacturer specifies a reduced measurement window at that rate. Check the bracketed range values for the exact model.
No. Specification footnotes require an interface module for certain outputs, including PROFINET, EtherNet/IP and analog output. Select the required connection chain.
Do not merge the terms. The model table labels it Resolution and specifies a 20 kHz test rate. Linearity is a separate row.
Its measurement electronics are integrated. Interface adapters or a DPU may still be needed for output conversion, system connection or two-sensor calculations.
No. Power, open-ended and interface-adapter cables serve different purposes. Match cable code, function, length and motion conditions to the configuration.