Skip to content

optoNCDT 2300 Laser triangulation

optoNCDT 2300: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT 2300
Measuring window 24–500 mm
Light spot width Y 0.07–0.38 mm
Light spot width X 0.03–0.38 mm
Measuring rate 20000–49140 Hz
rate_option 1500–49140 Hz
Measuring range 2–300 mm
Working distance 24–500 mm
Resolution 0.03–4.5 µm
Linearity 0.6–90 µm
Accuracy 0.6–90 µm
Light spot diameter 0.13–1.3 mm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT 2300 compared by parameter
Parameter ILD2300-10 eli-m-6a538433cb54bcfa4486e942 ILD2300-100 eli-m-11f5ea4909d939f1e2ce5b0f ILD2300-2 eli-m-dfffe354a94ee7173e18e707 ILD2300-20 eli-m-004914d0cc32515f361c90c0 ILD2300-200 eli-m-6f158e04ef7f13f957a2cc60 ILD2300-300 eli-m-c181774b9b329b6d6da0bf07 ILD2300-5 eli-m-3d2df53c0ba4585af90a7ea5 ILD2300-50 eli-m-d77dff06a3e04f6ba7d031ce
Measuring window 30–40 mm 70–170 mm 24–26 mm 40–60 mm 130–330 mm 200–500 mm 24–26 mm 45–95 mm
Light spot width Y 0.16 mm Not specified 0.08500000000000001 mm 0.2 mm Not specified 0.38 mm 0.08 mm 0.07000000000000001 mm
interface_specification Digital I/O Digital I/O Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Digital I/O Digital I/O
Protection class (DIN EN 60529) ip65 ip65 ip65 ip65 ip65 ip65 ip65 ip65
Light spot width X 0.11 mm Not specified 0.055 mm 0.14 mm Not specified 0.38 mm 0.03 mm 0.255 mm
Measuring rate 49140 Hz 20000 Hz 20000 Hz 49140 Hz 49140 Hz 49140 Hz 49140 Hz 49140 Hz
Interfaces ethercat ethercat ethernet ethercat ethernet ethercat ethercat ethernet
rate_option 49140 Hz 30000 Hz 30000 Hz 30000 Hz 1500 Hz 49140 Hz 30000 Hz 10000 Hz
Operating temperature 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C
Measuring range 10 mm 100 mm 2 mm 10 mm 200 mm 300 mm 2 mm 50 mm
Working distance 30–40 mm 70–170 mm 24–26 mm 40–60 mm 120–420 mm 200–500 mm 24–29 mm 45–95 mm
Resolution 0.15 µm 1.5 µm 0.03 µm 0.3 µm 3 µm 4.5 µm 0.08 µm 0.8 µm
quantity_specification 10 mm net measuring range; 30-40 mm sensor-to-target working window. 100 mm net measuring range; 70-170 mm sensor-to-target working window. 2 mm net measuring range; 24-26 mm sensor-to-target working window. 20 mm net measuring range; 40-60 mm sensor-to-target working window. Not specified 300 mm net measuring range; 200-500 mm sensor-to-target working window. 5 mm net measuring range; 24-29 mm sensor-to-target working window. 50 mm net measuring range; 45-95 mm sensor-to-target working window.
Linearity 2 µm 20 µm 0.6 µm 4 µm 60 µm 90 µm 1.5 µm 10 µm
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 2 µm 20 µm 0.6 µm 4 µm 60 µm 90 µm 1.5 µm 10 µm
ADC sampling rate 30000 samples/s 30000 samples/s 30000 samples/s 30000 samples/s 30000 samples/s 30000 samples/s 30000 samples/s 30000 samples/s
Light spot diameter Not specified 0.13 mm Not specified Not specified 1.3 mm Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active
Datasheet PDF — ILD2300-10 (opens in a new tab) PDF — ILD2300-100 (opens in a new tab) PDF — ILD2300-2 (opens in a new tab) PDF — ILD2300-20 (opens in a new tab) PDF — ILD2300-200 (opens in a new tab) PDF — ILD2300-300 (opens in a new tab) PDF — ILD2300-5 (opens in a new tab) PDF — ILD2300-50 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Not necessarily. The manufacturer specifies a reduced measurement window at that rate. Check the bracketed range values for the exact model.

No. Specification footnotes require an interface module for certain outputs, including PROFINET, EtherNet/IP and analog output. Select the required connection chain.

Do not merge the terms. The model table labels it Resolution and specifies a 20 kHz test rate. Linearity is a separate row.

Its measurement electronics are integrated. Interface adapters or a DPU may still be needed for output conversion, system connection or two-sensor calculations.

No. Power, open-ended and interface-adapter cables serve different purposes. Match cable code, function, length and motion conditions to the configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words