optoNCDT Laser Line Laser triangulation
optoNCDT Laser Line: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring rate | 4000–49140 Hz |
|---|---|
| Light spot width Y | 0.24–1.74 mm |
| Light spot width X | 0.055–0.3 mm |
| Start of measuring range | 15–40 mm |
| Repeatability | 0.1–2 µm |
| rate_option | 250–5000 Hz |
| End of measuring range | 17–90 mm |
| Supply voltage | 11–30 V |
| Measuring range | 2–50 mm |
| Linearity | 0.6–40 µm |
| Power consumption | 2–3 W |
| ADC sampling rate | 8000–49140 samples/s |
| Weight | 0.185–0.55 kg |
| Resolution | 0.03–0.8 µm |
| Measuring window | 24–95 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ILD1420-10LL eli-m-be2c49249485c3148e80265c | ILD1420-25LL eli-m-0350aeccdf99fcdc0d35a9f9 | ILD1420-50LL eli-m-d7fda445079663ab6451d64f | ILD1900-10LL eli-m-bb2371b54fac5c6f925bc88c | ILD1900-25LL eli-m-e85a89ce258b87ac601041c8 | ILD1900-2LL eli-m-cf853ca4793ba40a9ed986e5 | ILD1900-50LL eli-m-606189be3a346560bc4e1a7c | ILD1900-6LL eli-m-4e25cf8ea19a0e1141ea4e30 | ILD2300-10LL eli-m-8fdb4b1ad3d8bfec2af52048 | ILD2300-20LL eli-m-16d354ce8574967e91b10cb8 | ILD2300-2LL eli-m-6f9b324a5f57d6e427c2b0fb | ILD2300-50LL eli-m-ed2027fcf1f6c4ac57e8ed69 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Measuring rate | 8000 Hz | 8000 Hz | 8000 Hz | 4000 Hz | 10000 Hz | 4000 Hz | 10000 Hz | 4000 Hz | 20000 Hz | 49140 Hz | 49140 Hz | 20000 Hz |
| Light spot width Y | 0.635 mm | 0.93 mm | 1.17 mm | 0.73 mm | 0.9500000000000001 mm | 0.46 mm | 1.74 mm | 0.5650000000000001 mm | 0.585 mm | 0.485 mm | 0.24 mm | 0.32 mm |
| Operating temperature | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C |
| Light spot width X | 0.12 mm | 0.2 mm | 0.11 mm | 0.125 mm | 0.21 mm | 0.055 mm | 0.235 mm | 0.1 mm | 0.12 mm | 0.195 mm | 0.064 mm | 0.3 mm |
| Start of measuring range | 20 mm | 25 mm | 35 mm | 20 mm | 25 mm | 15 mm | 40 mm | 17 mm | Not specified | Not specified | Not specified | Not specified |
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip65 | ip65 | ip65 | ip65 |
| Repeatability | 0.5 µm | 1 µm | 2 µm | 0.4 µm | 0.8 µm | 0.1 µm | 1.6 µm | 0.25 µm | Not specified | Not specified | Not specified | Not specified |
| rate_option | 500 Hz | 500 Hz | 250 Hz | 2000 Hz | 250 Hz | 500 Hz | 2000 Hz | 1000 Hz | 2500 Hz | 5000 Hz | 5000 Hz | 1500 Hz |
| End of measuring range | 30 mm | 50 mm | 85 mm | 30 mm | 50 mm | 17 mm | 90 mm | 23 mm | Not specified | Not specified | Not specified | Not specified |
| interface_specification | RS422 / RS485 | RS422 / RS485 | Analog 0-10V | RS422 / RS485 | Analog 0-10V | Analog 0-10V | Analog 0-10V | RS422 / RS485 | Analog 0-10V | Analog 0-10V | RS422 / RS485 | RS422 / RS485 |
| Supply voltage | 11.2–30 V | 11.2–30 V | 11.2–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V | 11–30 V |
| Measuring range | 10 mm | 25 mm | 50 mm | 10 mm | 25 mm | 2 mm | 50 mm | 6 mm | 10 mm | 10 mm | 2 mm | 50 mm |
| Interfaces | ethernet | usb | ethernet | usb | ethercat | usb | ethernet | ethernet | usb | usb | ethernet | usb |
| Linearity | 8 µm | 20 µm | 40 µm | 2 µm | 5 µm | 1 µm | 10 µm | 1.2 µm | 2 µm | 4 µm | 0.6 µm | 10 µm |
| Laser class | v_42817cc171636767 | v_42817cc171636767 | v_42817cc171636767 | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Storage temperature | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C | -20–70 °C |
| source_material | Aluminum housing | Aluminum housing | Aluminum housing | Aluminum housing | Aluminum housing | Aluminum housing | Aluminum housing | Aluminum housing | Die-cast zinc housing | Die-cast zinc housing | Die-cast zinc housing | Die-cast zinc housing |
| Power consumption | 2 W | 2 W | 2 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W |
| Contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact | Non-contact |
| ADC sampling rate | 8000 samples/s | 8000 samples/s | 8000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 49140 samples/s | 49140 samples/s | 49140 samples/s | 49140 samples/s |
| Weight | Not specified | Not specified | Not specified | 0.3 kg | 0.185 kg | 0.3 kg | 0.185 kg | 0.185 kg | 0.55 kg | 0.55 kg | 0.55 kg | 0.55 kg |
| Resolution | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.15 µm | 0.3 µm | 0.03 µm | 0.8 µm |
| Measuring window | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 30–40 mm | 50–60 mm | 24–26 mm | 45–95 mm |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — ILD1420-10LL (opens in a new tab) | PDF — ILD1420-25LL (opens in a new tab) | PDF — ILD1420-50LL (opens in a new tab) | PDF — ILD1900-10LL (opens in a new tab) | PDF — ILD1900-25LL (opens in a new tab) | PDF — ILD1900-2LL (opens in a new tab) | PDF — ILD1900-50LL (opens in a new tab) | PDF — ILD1900-6LL (opens in a new tab) | PDF — ILD2300-10LL (opens in a new tab) | PDF — ILD2300-20LL (opens in a new tab) | PDF — ILD2300-2LL (opens in a new tab) | PDF — ILD2300-50LL (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
These versions project a short line for distance measurement on challenging surfaces such as shiny or textured metals. Select the LL platform for the application.
No. LL is an optical variant used across several series. Span, rate and linearity depend on the exact model, not the suffix alone.
No. The table distinguishes start, middle and end. State both spot/line dimensions and the specified working position.
Certain models do. Bracketed spans apply at 49.14 kHz. Check required working coverage against that rate-specific window.
No. Its linearity has specified target conditions. Suitability for challenging surfaces does not remove material, reflectance and angle checks.
Get a quote or advice
Tell us what you need and an engineer will come back to you.