Skip to content

thicknessCONTROL MTS 7202.T Laser triangulation

thicknessCONTROL MTS 7202.T: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of thicknessCONTROL MTS 7202.T
System accuracy 2–12 µm
Resolution 0.2–5.5 µm
Repeatability 0.4–2.4 µm

Models in the series

One column per model: what differs between the models of the series.

Models of thicknessCONTROL MTS 7202.T compared by parameter
Parameter thicknessCONTROL MTS 7202.T-10/250 eli-m-b7a6f4de9ca1a54f8690f942 thicknessCONTROL MTS 7202.T-10/500 eli-m-ca4328db9d403dab5e0fd31f thicknessCONTROL MTS 7202.T-2/250 eli-m-2765c87050f515395bfb6d79 thicknessCONTROL MTS 7202.T-2/500 eli-m-f97db7e809f77aaa5a0ad814 thicknessCONTROL MTS 7202.T-20/250 eli-m-1de6619c962c56c8e5149392 thicknessCONTROL MTS 7202.T-20/500 eli-m-c7ba4e771b0bcb2259848f69 thicknessCONTROL MTS 7202.T-40/250 eli-m-d48fdd5ccb7798406e57a4e6 thicknessCONTROL MTS 7202.T-40/500 eli-m-72ae5be6f547c9df7ee84e40
Interfaces ethernet profinet ethercat ethercat ethercat profinet ethernet ethercat
System accuracy 3.5 µm 3.5 µm 2 µm 2 µm 6 µm 6 µm 12 µm 12 µm
interface_specification Analog 0-10V Digital I/O Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Digital I/O Digital I/O
Resolution 0.6 µm 0.6 µm 0.2 µm 0.2 µm 2 µm 2 µm 5.5 µm 5.5 µm
source_repeatability_basis Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table.
quantity_specification 10 mm thickness measuring range; 250 mm named measuring width; article 4350127.12. 10 mm thickness measuring range; 500 mm named measuring width; article 4350127.16. 2 mm thickness measuring range; 250 mm named measuring width; article 4350127.11. 2 mm thickness measuring range; 500 mm named measuring width; article 4350127.15. 20 mm thickness measuring range; 250 mm named measuring width; article 4350127.13. 20 mm thickness measuring range; 500 mm named measuring width; article 4350127.17. 40 mm thickness measuring range; 250 mm named measuring width; article 4350127.14. 40 mm thickness measuring range; 500 mm named measuring width; article 4350127.18.
Repeatability 0.8 µm 0.8 µm 0.4 µm 0.4 µm 1.6 µm 1.6 µm 2.4 µm 2.4 µm
Maximum material width 250 mm 500 mm 250 mm 500 mm 250 mm 500 mm 250 mm 500 mm
Operating temperature 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Status Active Active Active Active Active Active Active Active
Datasheet PDF — thicknessCONTROL MTS 7202.T-10/250 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-10/500 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-2/250 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-2/500 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-20/250 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-20/500 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-40/250 (opens in a new tab) PDF — thicknessCONTROL MTS 7202.T-40/500 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

A C-frame thickness system using optoNCDT LL sensors and controller display, without an IPC in the documented configuration.

No. It describes an elliptical spot with averaging, not the same multi-point x/z profile definition as LLT.

No. Thickness span, operating gap, pass line and measuring width are distinct. Select the complete system configuration code.

No. Also check tabulated accuracy/repeatability, geometry, material, movement and environment. Small resolution is not a substitute for system accuracy.

Match calibration, sensor positions, motion and control interfaces to the selected configuration. Keep system data separate from head data and on-request options.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words