Skip to content

thicknessCONTROL MTS 8202.T Laser triangulation

thicknessCONTROL MTS 8202.T: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of thicknessCONTROL MTS 8202.T
System accuracy 0.5–4 µm
Resolution 0.06–1.1 µm
Repeatability 0.1–0.6 µm

Models in the series

One column per model: what differs between the models of the series.

Models of thicknessCONTROL MTS 8202.T compared by parameter
Parameter thicknessCONTROL MTS 8202.T-10/250 eli-m-dcf5ad48b98b3f44e2211429 thicknessCONTROL MTS 8202.T-10/500 eli-m-f28c9d839f0425c17a2a7979 thicknessCONTROL MTS 8202.T-2/250 eli-m-a5661c6a8ab574295ec2cbfe thicknessCONTROL MTS 8202.T-2/500 eli-m-948ab5c06a0476bfcd93d2a5 thicknessCONTROL MTS 8202.T-20/250 eli-m-4b60a942928c144d740ce5fe thicknessCONTROL MTS 8202.T-20/500 eli-m-9a678027f27bed9fe19569ce thicknessCONTROL MTS 8202.T-40/500 eli-m-947fb7bcdd3d0ea8215789a3 thicknessCONTROL MTS 8202.T-50/250 eli-m-116c4e0930db66738d2d2a24
Interfaces profinet profinet ethernet ethernet profinet ethercat profinet ethernet
source_repeatability_basis Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table.
System accuracy 0.9 µm 0.9 µm 0.5 µm 0.5 µm 3 µm 3 µm 4 µm 4 µm
interface_specification Digital I/O Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V
Resolution 0.18 µm 0.18 µm 0.06 µm 0.06 µm 0.45 µm 0.45 µm 1.1 µm 1.1 µm
Maximum material width 250 mm 500 mm 250 mm 500 mm 250 mm 500 mm 500 mm 250 mm
Operating temperature 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C
quantity_specification 10 mm thickness measuring range; 250 mm named measuring width; article 4350127.02. 10 mm thickness measuring range; 500 mm named measuring width; article 4350127.06. 2 mm thickness measuring range; 250 mm named measuring width; article 4350127.01. 2 mm thickness measuring range; 500 mm named measuring width; article 4350127.05. 20 mm thickness measuring range; 250 mm named measuring width; article 4350127.03. 20 mm thickness measuring range; 500 mm named measuring width; article 4350127.07. 40 mm thickness measuring range; 500 mm named measuring width; article 4350127.08. 50 mm thickness measuring range; 250 mm named measuring width; article 4350127.04.
Repeatability 0.2 µm 0.2 µm 0.1 µm 0.1 µm 0.4 µm 0.4 µm 0.6 µm 0.6 µm
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Status Active Active Active Active Active Active Active Active
Datasheet PDF — thicknessCONTROL MTS 8202.T-10/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-10/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-2/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-2/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-20/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-20/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-40/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.T-50/250 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

A thickness system with different sensor performance from 7202.T and an IPC/evaluation software. Drive selection affects fixed-track versus traversal use.

No. Separate system tables and higher-precision 8202.T sensors are documented. Use the exact model/span.

No. Thickness span, operating gap, pass line and measuring width are distinct. Select the complete system configuration code.

No. Also check tabulated accuracy/repeatability, geometry, material, movement and environment. Small resolution is not a substitute for system accuracy.

Match calibration, sensor positions, motion and control interfaces to the selected configuration. Keep system data separate from head data and on-request options.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words