optoCONTROL 1200
optoCONTROL 1200: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Resolution | 8–30 µm |
|---|---|
| Accuracy (% FSO) | 2–3.5 % |
| Repeatability | 16–60 µm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | ODC1200-10 eli-m-a905774481765e7c808c975d | ODC1200-16 eli-m-f120b0b294baefbfbc113097 | ODC1200-2 eli-m-3d57bac7616ccebd339003d0 | ODC1200-5 eli-m-931d4d927c8a4eea4476cb79 | ODC1200/90-10 eli-m-4aa4d6c3e5cd3c7390d9d57a | ODC1200/90-16 eli-m-844eedca26cea7fd9ae4cf6e | ODC1200/90-2 eli-m-27fb7bbc26d182c6900af152 | ODC1200/90-5 eli-m-1f772d90295d0be5dd487334 |
|---|---|---|---|---|---|---|---|---|
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 |
| Output update rate | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz | 4000 Hz |
| source_sampling_rate_basis | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s | 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s |
| Resolution | 20 µm | 30 µm | 8 µm | 10 µm | 20 µm | 30 µm | 8 µm | 10 µm |
| interface_specification | Analog 0-10V | Digital I/O | Analog 0-10V | Analog 0-10V | Analog 0-10V | Analog 0-10V | Analog 0-10V | Digital I/O |
| Measuring rate | 100000 Hz | 100000 Hz | 100000 Hz | 100000 Hz | 100000 Hz | 100000 Hz | 100000 Hz | 100000 Hz |
| Interfaces | ethernet | ethernet | ethernet | ethernet | ethernet | ethercat | ethernet | ethercat |
| ADC sampling rate | 100000 samples/s | 100000 samples/s | 100000 samples/s | 100000 samples/s | 100000 samples/s | 100000 samples/s | 100000 samples/s | 100000 samples/s |
| Accuracy (% FSO) | 2 % | 2 % | 2 % | 2 % | 3.5 % | 3.5 % | 3.5 % | 3.5 % |
| quantity_specification | 10 mm measuring range; 20 µm resolution; 40 µm repeatability; axial beam path. | 16 mm measuring range; 30 µm resolution; 60 µm repeatability; axial beam path. | 2 mm measuring range; 8 µm resolution; 16 µm repeatability; axial beam path. | 5 mm measuring range; 10 µm resolution; 20 µm repeatability; axial beam path. | 10 mm measuring range; 20 µm resolution; 40 µm repeatability; 90-degree beam path. | 16 mm measuring range; 30 µm resolution; 60 µm repeatability; 90-degree beam path. | 2 mm measuring range; 8 µm resolution; 16 µm repeatability; 90-degree beam path. | 5 mm measuring range; 10 µm resolution; 20 µm repeatability; 90-degree beam path. |
| Working distance | 20–2000 mm | 20–2000 mm | 20–2000 mm | 20–2000 mm | 20–2000 mm | 20–2000 mm | 20–2000 mm | 20–2000 mm |
| Operating temperature | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C | 0–50 °C |
| Repeatability | 40 µm | 60 µm | 16 µm | 20 µm | 40 µm | 60 µm | 16 µm | 20 µm |
| Status | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — ODC1200-10 (opens in a new tab) | PDF — ODC1200-16 (opens in a new tab) | PDF — ODC1200-2 (opens in a new tab) | PDF — ODC1200-5 (opens in a new tab) | PDF — ODC1200/90-10 (opens in a new tab) | PDF — ODC1200/90-16 (opens in a new tab) | PDF — ODC1200/90-2 (opens in a new tab) | PDF — ODC1200/90-5 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. Evaluation electronics are integrated; provide appropriate power and connection to the receiving system.
No. The listed separate measuring-range variants are 2, 5, 10, 16, 20 and 30 mm.
No. The manufacturer specifies 100 kHz measurement and up to 60 kHz switching. These are different specifications.
Range alone does not establish accuracy. Read the selected model’s linearity and resolution and verify target coverage.
A measuring output supports evaluation of the measured size; a threshold output changes state at a switching condition. Select the signal type required by the system.
Get a quote or advice
Tell us what you need and an engineer will come back to you.