scanCONTROL 2900
scanCONTROL 2900: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Accuracy | 1–12 µm |
|---|---|
| X resolution | 8.359375–112.109375 µm |
| Z measuring range | 8–265 mm |
| X measuring range | 10.7–143.5 mm |
| Working distance | 52.5–390 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | scanCONTROL 2900-10 eli-m-ad45172d8331e6ca08bf4070 | scanCONTROL 2900-100 eli-m-bb14ed39243a4a319c874e01 | scanCONTROL 2900-25 eli-m-7535860964bf956006a0325f | scanCONTROL 2900-50 eli-m-bc9c9c4aa16049d6e8728575 |
|---|---|---|---|---|
| Accuracy | 1 µm | 12 µm | 2 µm | 4 µm |
| X resolution | 8.359375 µm | 112.109375 µm | 22.890625 µm | 46.875 µm |
| Interfaces | ethernet | ethernet | ethercat | profinet |
| Operating temperature | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C |
| Z measuring range | 8 mm | 265 mm | 26 mm | 60 mm |
| Protection class (DIN EN 60529) | ip65 | ip65 | ip65 | ip65 |
| Points per profile | 1280 points/profile | 1280 points/profile | 1280 points/profile | 1280 points/profile |
| source_three_d_scanner_type | Laser line | Laser line | Laser line | Laser line |
| ADC sampling rate | 300 samples/s | 300 samples/s | 300 samples/s | 300 samples/s |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| source_sampling_rate_basis | scanCONTROL 2900-10 catalog maximum profile frequency | scanCONTROL 2900-100 catalog maximum profile frequency | scanCONTROL 2900-25 catalog maximum profile frequency | scanCONTROL 2900-50 catalog maximum profile frequency |
| Y measuring range | 0 mm | 0 mm | 0 mm | 0 mm |
| quantity_specification | X field up to 10.7 mm and Z range up to 8 mm; Y is generated by encoder-synchronized travel. | X field up to 143.5 mm and Z range up to 265 mm; Y is generated by encoder-synchronized travel. | X field up to 29.3 mm and Z range up to 26 mm; Y is generated by encoder-synchronized travel. | X field up to 60 mm and Z range up to 60 mm; Y is generated by encoder-synchronized travel. |
| X measuring range | 10.7 mm | 143.5 mm | 29.3 mm | 60 mm |
| Working distance | 52.5–60.5 mm | 125–390 mm | 53–79 mm | 65–125 mm |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — scanCONTROL 2900-10 (opens in a new tab) | PDF — scanCONTROL 2900-100 (opens in a new tab) | PDF — scanCONTROL 2900-25 (opens in a new tab) | PDF — scanCONTROL 2900-50 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is PROFILE. It provides calibrated profiles for external processing; do not assign another model’s SMART program.
No. Its documented speed class is up to 300 Hz, with 1280 points per profile. Application performance also depends on exposure and acquisition configuration.
No. Also match z interval, start distance, distance-dependent x width and model linearity. Extended range is distinguished from standard range.
Profiles are transferred over Ethernet/GigE Vision for suitable software. Plan evaluation/output for control values rather than assuming onboard SMART output.
Suffixes such as BL, SI, PT and VT identify different options. Use the exact model code; do not transfer another variant’s image, wiring or safety feature.
Get a quote or advice
Tell us what you need and an engineer will come back to you.