Range across models
The span covered by the models of the series together — not the range of each model.
| X resolution | 8.359375–112.109375 µm |
|---|---|
| Working distance | 52.5–390 mm |
| X measuring range | 10.7–143.5 mm |
| Accuracy | 1–12 µm |
| Z measuring range | 8–265 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | scanCONTROL 2960-10 eli-m-7c123937dbd5cb45f0621a61 | scanCONTROL 2960-100 eli-m-d26c83fb7fa3e9938c755f5e | scanCONTROL 2960-25 eli-m-b8088ad87d5654db2726ea0d | scanCONTROL 2960-50 eli-m-809ca4c46a6642fe1b3a178c |
|---|---|---|---|---|
| Interfaces | ethercat | ethercat | ethernet | ethernet |
| X resolution | 8.359375 µm | 112.109375 µm | 22.890625 µm | 46.875 µm |
| source_sampling_rate_basis | scanCONTROL 2960-10 catalog maximum profile frequency | scanCONTROL 2960-100 catalog maximum profile frequency | scanCONTROL 2960-25 catalog maximum profile frequency | scanCONTROL 2960-50 catalog maximum profile frequency |
| Protection class (DIN EN 60529) | ip65 | ip65 | ip65 | ip65 |
| Operating temperature | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C |
| Y measuring range | 0 mm | 0 mm | 0 mm | 0 mm |
| Working distance | 52.5–60.5 mm | 125–390 mm | 53–79 mm | 65–125 mm |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| ADC sampling rate | 2000 samples/s | 2000 samples/s | 2000 samples/s | 2000 samples/s |
| source_three_d_scanner_type | Laser line | Laser line | Laser line | Laser line |
| Points per profile | 1280 points/profile | 1280 points/profile | 1280 points/profile | 1280 points/profile |
| quantity_specification | X field up to 10.7 mm and Z range up to 8 mm; Y is generated by encoder-synchronized travel. | X field up to 143.5 mm and Z range up to 265 mm; Y is generated by encoder-synchronized travel. | X field up to 29.3 mm and Z range up to 26 mm; Y is generated by encoder-synchronized travel. | X field up to 60 mm and Z range up to 60 mm; Y is generated by encoder-synchronized travel. |
| X measuring range | 10.7 mm | 143.5 mm | 29.3 mm | 60 mm |
| Accuracy | 1 µm | 12 µm | 2 µm | 4 µm |
| Z measuring range | 8 mm | 265 mm | 26 mm | 60 mm |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — scanCONTROL 2960-10 (opens in a new tab) | PDF — scanCONTROL 2960-100 (opens in a new tab) | PDF — scanCONTROL 2960-25 (opens in a new tab) | PDF — scanCONTROL 2960-50 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It is HIGHSPEED-SMART. The head calculates measurement values using a program configured in Configuration Tools.
Yes. Its documented speed class is up to 2 kHz, with 1280 points per profile. Application performance also depends on exposure and acquisition configuration.
No. Also match z interval, start distance, distance-dependent x width and model linearity. Extended range is distinguished from standard range.
SMART results use the documented interfaces; Industrial Ethernet needs a gateway and analog conversion an Output Unit. Check end-to-end rate.
Suffixes such as BL, SI, PT and VT identify different options. Use the exact model code; do not transfer another variant’s image, wiring or safety feature.