scanCONTROL 3000
scanCONTROL 3000: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Accuracy | 1.5–26 µm |
|---|---|
| X measuring range | 26.8–788 mm |
| Z measuring range | 15–600 mm |
| X resolution | 13.085938–384.765625 µm |
| Working distance | 77.5–1050 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | scanCONTROL 3000-100 eli-m-97192f00f8d5bf414e0efb5f | scanCONTROL 3000-200 eli-m-8d7dd8b42d91709d7961bcee | scanCONTROL 3000-25 eli-m-1ce75c3cece3560c931bf7e5 | scanCONTROL 3000-430 eli-m-234ddee3706f3559e6c48d2b | scanCONTROL 3000-50 eli-m-b88ee824d7016dd4a5ba24d5 | scanCONTROL 3000-600 eli-m-dbfeb1163ad241e19c580a4f |
|---|---|---|---|---|---|---|
| Operating temperature | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C |
| Y measuring range | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm |
| Interfaces | profinet | profinet | ethercat | ethercat | ethercat | ethernet |
| Points per profile | 2048 points/profile | 2048 points/profile | 2048 points/profile | 2048 points/profile | 2048 points/profile | 2048 points/profile |
| source_sampling_rate_basis | scanCONTROL 3000-100 catalog maximum profile frequency | scanCONTROL 3000-200 catalog maximum profile frequency | scanCONTROL 3000-25 catalog maximum profile frequency | scanCONTROL 3000-430 catalog maximum profile frequency | scanCONTROL 3000-50 catalog maximum profile frequency | scanCONTROL 3000-600 catalog maximum profile frequency |
| quantity_specification | X field up to 131.3 mm and Z range up to 170 mm; Y is generated by encoder-synchronized travel. | X field up to 290 mm and Z range up to 300 mm; Y is generated by encoder-synchronized travel. | X field up to 26.8 mm and Z range up to 15 mm; Y is generated by encoder-synchronized travel. | X field up to 560 mm and Z range up to 390 mm; Y is generated by encoder-synchronized travel. | X field up to 56.5 mm and Z range up to 40 mm; Y is generated by encoder-synchronized travel. | X field up to 788 mm and Z range up to 600 mm; Y is generated by encoder-synchronized travel. |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| Accuracy | 9 µm | 26 µm | 1.5 µm | 12 µm | 3 µm | 15 µm |
| source_three_d_scanner_type | Laser line | Laser line | Laser line | Laser line | Laser line | Laser line |
| X measuring range | 131.3 mm | 290 mm | 26.8 mm | 560 mm | 56.5 mm | 788 mm |
| ADC sampling rate | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s |
| Z measuring range | 170 mm | 300 mm | 15 mm | 390 mm | 40 mm | 600 mm |
| X resolution | 64.111328125 µm | 141.6015625 µm | 13.0859375 µm | 273.4375 µm | 27.587890625 µm | 384.765625 µm |
| Working distance | 190–360 mm | 160–460 mm | 77.5–92.5 mm | 330–720 mm | 105–145 mm | 450–1050 mm |
| Protection class (DIN EN 60529) | ip67 | ip67 | ip40 | ip67 | ip67 | ip67 |
| Status | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — scanCONTROL 3000-100 (opens in a new tab) | PDF — scanCONTROL 3000-200 (opens in a new tab) | PDF — scanCONTROL 3000-25 (opens in a new tab) | PDF — scanCONTROL 3000-430 (opens in a new tab) | PDF — scanCONTROL 3000-50 (opens in a new tab) | PDF — scanCONTROL 3000-600 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
PROFILE provides calibrated profiles for external software. It is not the SMART version for autonomous dimension evaluation.
They are the x points per profile. Z linearity is separate and field-dependent; point count is not directly equivalent to micrometer accuracy.
No. Z start, middle and end vary by model. X field width also varies across z, so check coverage throughout target movement.
Relative movement and suitable position information, plus processing software or a system unit as required. One profile is not a full 3D snapshot.
Ethernet/GigE Vision and documented power methods include PoE. Select wiring for profile data, without automatically assigning SMART outputs.
Get a quote or advice
Tell us what you need and an engineer will come back to you.