scanCONTROL 3010
scanCONTROL 3010: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Working distance | 40–1050 mm |
|---|---|
| Z measuring range | 15–600 mm |
| X resolution | 13.085938–384.765625 µm |
| Accuracy | 1.5–26 µm |
| X measuring range | 26.8–788 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | scanCONTROL 3010-100 eli-m-0038734bbcaa6db770602e1f | scanCONTROL 3010-200 eli-m-82aeb8de94c21cc0d9503851 | scanCONTROL 3010-25 eli-m-81a091b9a8da74e923de6557 | scanCONTROL 3010-25/BL eli-m-31b07a24a68c2ed33c0bbe36 | scanCONTROL 3010-430 eli-m-9be64b63dcc2db27f6da831c | scanCONTROL 3010-50 eli-m-8a45ded31a8d616bc23c7c1f | scanCONTROL 3010-600 eli-m-7b84194d904e08aad72246f4 |
|---|---|---|---|---|---|---|---|
| Interfaces | profinet | ethercat | profinet | ethercat | ethernet | profinet | ethernet |
| Working distance | 190–360 mm | 160–460 mm | 77.5–92.5 mm | 40–140 mm | 330–720 mm | 105–145 mm | 450–1050 mm |
| Points per profile | 2048 points/profile | 2048 points/profile | 2048 points/profile | Not specified | 2048 points/profile | 2048 points/profile | 2048 points/profile |
| Protection class (DIN EN 60529) | ip67 | ip40 | ip67 | ip40 | ip67 | ip67 | ip67 |
| Z measuring range | 170 mm | 300 mm | 15 mm | 25 mm | 390 mm | 40 mm | 600 mm |
| Operating temperature | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C | 0–45 °C |
| Y measuring range | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm |
| interface_specification | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O | Digital I/O |
| source_three_d_scanner_type | Laser line | Laser line | Laser line | Not specified | Laser line | Laser line | Laser line |
| X resolution | 64.111328125 µm | 141.6015625 µm | 13.0859375 µm | Not specified | 273.4375 µm | 27.587890625 µm | 384.765625 µm |
| ADC sampling rate | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s | 10000 samples/s |
| Accuracy | 9 µm | 26 µm | 1.5 µm | 1.5 µm | 12 µm | 3 µm | 15 µm |
| quantity_specification | X field up to 131.3 mm and Z range up to 170 mm; Y is generated by encoder-synchronized travel. | X field up to 290 mm and Z range up to 300 mm; Y is generated by encoder-synchronized travel. | X field up to 26.8 mm and Z range up to 15 mm; Y is generated by encoder-synchronized travel. | Not specified | X field up to 560 mm and Z range up to 390 mm; Y is generated by encoder-synchronized travel. | X field up to 56.5 mm and Z range up to 40 mm; Y is generated by encoder-synchronized travel. | X field up to 788 mm and Z range up to 600 mm; Y is generated by encoder-synchronized travel. |
| X measuring range | 131.3 mm | 290 mm | 26.8 mm | 30 mm | 560 mm | 56.5 mm | 788 mm |
| source_sampling_rate_basis | scanCONTROL 3010-100 catalog maximum profile frequency | scanCONTROL 3010-200 catalog maximum profile frequency | scanCONTROL 3010-25 catalog maximum profile frequency | Not specified | scanCONTROL 3010-430 catalog maximum profile frequency | scanCONTROL 3010-50 catalog maximum profile frequency | scanCONTROL 3010-600 catalog maximum profile frequency |
| Status | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — scanCONTROL 3010-100 (opens in a new tab) | PDF — scanCONTROL 3010-200 (opens in a new tab) | PDF — scanCONTROL 3010-25 (opens in a new tab) | PDF — scanCONTROL 3010-25/BL (opens in a new tab) | PDF — scanCONTROL 3010-430 (opens in a new tab) | PDF — scanCONTROL 3010-50 (opens in a new tab) | PDF — scanCONTROL 3010-600 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The SMART head evaluates dimensions from the profile using its stored measurement program.
They are the x points per profile. Z linearity is separate and field-dependent; point count is not directly equivalent to micrometer accuracy.
No. Z start, middle and end vary by model. X field width also varies across z, so check coverage throughout target movement.
Relative movement and suitable position information, plus processing software or a system unit as required. One profile is not a full 3D snapshot.
Select an Output Unit or gateway for the required SMART output. Separately check transfer rate, sensor count, wiring and PoE option.
Get a quote or advice
Tell us what you need and an engineer will come back to you.