Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of scanCONTROL 3012
X resolution 26.171875–769.53125 µm
Z measuring range 15–600 mm
Working distance 77.5–1050 mm
Accuracy 2–30 µm
X measuring range 26.8–788 mm

Models in the series

One column per model: what differs between the models of the series.

Models of scanCONTROL 3012 compared by parameter
Parameter scanCONTROL 3012-100 eli-m-20181b5ed18068c0ef82064d scanCONTROL 3012-200 eli-m-51db2788a397b13775197443 scanCONTROL 3012-25 eli-m-7d95a1f90581945b7b31d4b9 scanCONTROL 3012-430 eli-m-98d76f97f4a4e9b051f5aa0c scanCONTROL 3012-50 eli-m-af4b1d407a2da6d931187cbc scanCONTROL 3012-600 eli-m-ec99959a4d5c474f2a52899c
X resolution 128.22265625 µm 283.203125 µm 26.171875 µm 546.875 µm 55.17578125 µm 769.53125 µm
Protection class (DIN EN 60529) ip67 ip67 ip67 ip40 ip67 ip67
Z measuring range 170 mm 300 mm 15 mm 390 mm 40 mm 600 mm
Operating temperature 0–45 °C 0–45 °C 0–45 °C 0–45 °C 0–45 °C 0–45 °C
quantity_specification X field up to 131.3 mm and Z range up to 170 mm; Y is generated by encoder-synchronized travel. X field up to 290 mm and Z range up to 300 mm; Y is generated by encoder-synchronized travel. X field up to 26.8 mm and Z range up to 15 mm; Y is generated by encoder-synchronized travel. X field up to 560 mm and Z range up to 390 mm; Y is generated by encoder-synchronized travel. X field up to 56.5 mm and Z range up to 40 mm; Y is generated by encoder-synchronized travel. X field up to 788 mm and Z range up to 600 mm; Y is generated by encoder-synchronized travel.
source_three_d_scanner_type Laser line Laser line Laser line Laser line Laser line Laser line
Interfaces ethercat ethercat ethernet ethercat ethernet ethercat
ADC sampling rate 10000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s
interface_specification Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
source_sampling_rate_basis scanCONTROL 3012-100 catalog maximum profile frequency scanCONTROL 3012-200 catalog maximum profile frequency scanCONTROL 3012-25 catalog maximum profile frequency scanCONTROL 3012-430 catalog maximum profile frequency scanCONTROL 3012-50 catalog maximum profile frequency scanCONTROL 3012-600 catalog maximum profile frequency
Working distance 190–360 mm 160–460 mm 77.5–92.5 mm 330–720 mm 105–145 mm 450–1050 mm
Points per profile 1024 points/profile 1024 points/profile 1024 points/profile 1024 points/profile 1024 points/profile 1024 points/profile
Accuracy 10 µm 30 µm 2 µm 15 µm 4 µm 22 µm
Y measuring range 0 mm 0 mm 0 mm 0 mm 0 mm 0 mm
X measuring range 131.3 mm 290 mm 26.8 mm 560 mm 56.5 mm 788 mm
Status Active Active Active Active Active Active
Datasheet PDF — scanCONTROL 3012-100 (opens in a new tab) PDF — scanCONTROL 3012-200 (opens in a new tab) PDF — scanCONTROL 3012-25 (opens in a new tab) PDF — scanCONTROL 3012-430 (opens in a new tab) PDF — scanCONTROL 3012-50 (opens in a new tab) PDF — scanCONTROL 3012-600 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The SMART head evaluates dimensions from the profile using its stored measurement program.

They are the x points per profile. Z linearity is separate and field-dependent; point count is not directly equivalent to micrometer accuracy.

No. Z start, middle and end vary by model. X field width also varies across z, so check coverage throughout target movement.

Relative movement and suitable position information, plus processing software or a system unit as required. One profile is not a full 3D snapshot.

Select an Output Unit or gateway for the required SMART output. Separately check transfer rate, sensor count, wiring and PoE option.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words