scanCONTROL 8×00
scanCONTROL 8x00: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
This series on the Micro-Epsilon site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | scanCONTROL 8200 / 8500 eli-m-ba199001cbda67c6742f2e85 |
|---|---|
| interface_specification | Digital I/O |
| Working distance | 50–650 mm |
| Protection class (DIN EN 60529) | ip67 |
| ADC sampling rate | 10000 samples/s |
| X measuring range | 115 mm |
| Operating temperature | 0–35 °C |
| Z measuring range | 95 mm |
| quantity_specification | Use 8200/8500 when high point density, green laser stability, or top-tier line-profile performance is required |
| Interfaces | ethernet |
| Y measuring range | 0 mm |
| Status | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Tables specify 2112 profile points for 8200 and 4224 for 8500. Family membership does not make lateral resolution equivalent.
The family describes SMART and 3D DATA operation: configure a program in 3DInspect or transmit calibrated data for external processing according to mode.
No. It is the listed maximum profile frequency. A 3D program’s result rate depends on acquisition, profile count and evaluation.
Yes. The catalogue footnote reduces IP67 to IP40 with the optional active cooling unit. Preserve the cooling configuration with the rating.
Not automatically. The Output/Gateway list excludes 8x00, whose model tables define their own interfaces. Select by series configuration.
Get a quote or advice
Tell us what you need and an engineer will come back to you.