Range across the models of thicknessCONTROL MTS 8202.LLT
System accuracy 2–20 µm
Resolution 0.2–2 µm

Models in the series

One column per model: what differs between the models of the series.

Models of thicknessCONTROL MTS 8202.LLT compared by parameter
Parameter thicknessCONTROL MTS 8202.LLT-400/1000 eli-m-6b81ae52ab4ebb3361ac3f4d thicknessCONTROL MTS 8202.LLT-400/1500 eli-m-bd366f380e6c02208e070e61 thicknessCONTROL MTS 8202.LLT-400/2000 eli-m-8032babcafd16d02e1d27b50 thicknessCONTROL MTS 8202.LLT-400/250 eli-m-6e5000740c74dbe5069a3c60 thicknessCONTROL MTS 8202.LLT-400/2500 eli-m-b3206bf78dc45f7ebe397bf9 thicknessCONTROL MTS 8202.LLT-400/500 eli-m-da35080c09b82ab1ad2c8a71 thicknessCONTROL MTS 8202.LLT-60/1000 eli-m-1c3d4b6bcc7727dcc9ac6754 thicknessCONTROL MTS 8202.LLT-60/1500 eli-m-469bab3751fd1447f21c235b thicknessCONTROL MTS 8202.LLT-60/2000 eli-m-97c13bafd9157eda69b7ebb7 thicknessCONTROL MTS 8202.LLT-60/250 eli-m-310b9396551cd5b815a28cfc thicknessCONTROL MTS 8202.LLT-60/2500 eli-m-c46600ca01a004ad85ea4da4 thicknessCONTROL MTS 8202.LLT-60/500 eli-m-cf31cc4b5027134687f80809
System accuracy 20 µm 20 µm 20 µm 20 µm 20 µm 20 µm 2 µm 2 µm 2 µm 2 µm 2 µm 2 µm
quantity_specification 400 mm thickness measuring range; 1000 mm named measuring width; article 4350127.72. 400 mm thickness measuring range; 1500 mm named measuring width; article 4350127.344. 400 mm thickness measuring range; 2000 mm named measuring width; article 4350127.345. 400 mm thickness measuring range; 250 mm named measuring width; article 4350127.22. 400 mm thickness measuring range; 2500 mm named measuring width; article 4350127.346. 400 mm thickness measuring range; 500 mm named measuring width; article 4350127.24. 60 mm thickness measuring range; 1000 mm named measuring width; article 4350127.71. 60 mm thickness measuring range; 1500 mm named measuring width; article 4350127.326. 60 mm thickness measuring range; 2000 mm named measuring width; article 4350127.318. 60 mm thickness measuring range; 250 mm named measuring width; article 4350127.21. 60 mm thickness measuring range; 2500 mm named measuring width; article 4350127.343. 60 mm thickness measuring range; 500 mm named measuring width; article 4350127.23.
interface_specification Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Digital I/O Analog 0-10V Analog 0-10V
Operating temperature 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C
Repeatability 5 µm 5 µm 5 µm 5 µm 5 µm 5 µm 0.5 µm 0.5 µm 0.5 µm 0.5 µm 0.5 µm 0.5 µm
Interfaces ethernet profinet ethernet ethercat profinet ethercat ethernet ethercat ethercat ethernet ethercat ethernet
Maximum material width 1000 mm 1500 mm 2000 mm 250 mm 2500 mm 500 mm 1000 mm 1500 mm 2000 mm 250 mm 2500 mm 500 mm
Resolution 2 µm 2 µm 2 µm 2 µm 2 µm 2 µm 0.2 µm 0.2 µm 0.2 µm 0.2 µm 0.2 µm 0.2 µm
Repeatability Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — thicknessCONTROL MTS 8202.LLT-400/1000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-400/1500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-400/2000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-400/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-400/2500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-400/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/1000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/1500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/2000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/2500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.LLT-60/500 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

A C-frame laser-profile thickness system for structured surfaces and demanding industrial conditions.

No. Its table separates two intervals with different accuracy/resolution. Preserve the boundaries of each.

No. Thickness span, operating gap, pass line and measuring width are distinct. Select the complete system configuration code.

No. Also check tabulated accuracy/repeatability, geometry, material, movement and environment. Small resolution is not a substitute for system accuracy.

Match calibration, sensor positions, motion and control interfaces to the selected configuration. Keep system data separate from head data and on-request options.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words