C.LL-6/400

From the thicknessGAUGE C.LL series

Inline thickness measurement system with two laser triangulation sensors, automatic calibration and a traversing unit. System performance is specified per model.

System accuracy
1 µm
Measuring range
6 mm
Measuring width
400 mm
Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for C.LL-6/400
Measuring width 400 mm
Measuring range 6 mm
source_maximum_travel_path_mm 580 mm
System accuracy 1 µm
Resolution 0.1 µm
Measuring rate 10000 Hz
Maximum material width 400 mm
source_system_calibration_type Automatic
Interfaces ethernet
interface_specification Analog 0-10V
Humidity 5–95 %RH
Protection class (DIN EN 60529) ip40
Storage temperature -20–65 °C
quantity_specification 6 mm thickness measuring range; 400 mm named measuring width.
Operating temperature 5–45 °C
Operating range 33 mm
interface_specification Digital I/O
Interfaces ethercat
source_sampling_rate_basis Official maximum measurement or output rate: 10,000 Hz.
source_repeatability_basis Repeatability not stated in the reviewed official source.
Interfaces profinet
Protection class (DIN EN 60529) ip54
Request a quote for this product

Compatible accessories

Complementary products

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words