thicknessGAUGE C.LP
thicknessGAUGE C.LP: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.
Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Protection class (DIN EN 60529) | ip54 |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | C.LP-15/200 eli-m-17f6a2f86563692b9200f2b3 | C.LP-15/400 eli-m-32e4b86dcbc2aa25f813c15a | C.LP-15/600 eli-m-f56ed4614a2d772f043d09ed |
|---|---|---|---|
| Protection class (DIN EN 60529) | ip40 | ip54 | ip40 |
| Interfaces | ethernet | profinet | ethernet |
| source_system_calibration_type | Automatic | Automatic | Automatic |
| System accuracy | 1.2 µm | 1.2 µm | 1.2 µm |
| interface_specification | OPC UA | Analog 0-10V | Analog 0-10V |
| Measuring range | 15 mm | Not specified | Not specified |
| Resolution | 0.2 µm | 0.2 µm | 0.2 µm |
| Storage temperature | -20–65 °C | -20–65 °C | -20–65 °C |
| quantity_specification | 15 mm thickness measuring range; 200 mm named measuring width. | 15 mm thickness range, 400 mm measuring width, C-frame with two laser profile scanners. | 15 mm thickness measuring range; 600 mm named measuring width. |
| Measuring rate | 100 Hz | 100 Hz | 100 Hz |
| source_repeatability_basis | Repeatability not stated in the reviewed official source. | Not specified | Repeatability not stated in the reviewed official source. |
| Humidity | 5–95 %RH | 5–95 %RH | 5–95 %RH |
| Operating range | 144 mm | 144 mm | 144 mm |
| Operating temperature | 5–45 °C | 5–45 °C | 5–45 °C |
| source_sampling_rate_basis | Official maximum measurement or output rate: 100 Hz. | Not specified | Official maximum measurement or output rate: 100 Hz. |
| source_maximum_travel_path_mm | 380 mm | 580 mm | 780 mm |
| Laser class | v_4da3f93c6d2ec7a8 | v_4da3f93c6d2ec7a8 | v_4da3f93c6d2ec7a8 |
| system_interface_options | profinet | ethernet_ip | ethernet_ip |
| Maximum material width | 200 mm | 400 mm | 600 mm |
| ADC sampling rate | 100 samples/s | Not specified | 100 samples/s |
| Working distance | Not specified | 0–144 mm | Not specified |
| Status | Active | Active | Active |
| Datasheet | PDF — C.LP-15/200 (opens in a new tab) | PDF — C.LP-15/400 (opens in a new tab) | PDF — C.LP-15/600 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It uses opposed laser-profile sensors for thickness. Profiles support structured surfaces and strip-tilt handling according to the measurement program.
No. The catalogue specifies up to 100 Hz for C.LP. Do not use maximum head profile frequency as thickness-system rate.
Thickness span belongs to the thickness axis. Profile width and mechanical traverse width are separate dimensions, not one range filter.
No. It is a profile-based thickness system. General 3D geometry needs a corresponding configuration/program, such as the appropriate 3D family.
Heads need mutual alignment and calibrated baseline. Automatic calibration against the parked standard helps maintain stable thickness measurement.
Get a quote or advice
Tell us what you need and an engineer will come back to you.