Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C15
Force range 0–1000000 N
ADC sampling rate 450–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of C15 compared by parameter
Parameter C15 eli-m-957109b4dc1c43bfdb1ae1a4 C15-1000kN eli-m-ca7f00d15a14d5262d70acc6 C15-100kN eli-m-e7e0fd2a3915fbabb5cbc4b7 C15-10kN eli-m-07866ea20282621b22ecd4b0 C15-250kN eli-m-8cb5e5c21a79586ceb7c40d2 C15-25kN eli-m-c6bd362ec00ca1e8609b5876 C15-2p5kN eli-m-c661cc4efdd16dea5b8f51b4 C15-500kN eli-m-248033a048331df28d96352c C15-50kN eli-m-ff502465bb85c7da950f1e37 C15-5kN eli-m-8d08c8d1ec012655b7044f5d
interface_specification Unknown RS422 / RS485 RS422 / RS485 RS422 / RS485 Analog 0-10V Analog 0-10V Digital I/O Digital I/O Digital I/O Digital I/O
quantity_specification Configurable family; exact public ordering-code table not exposed on the current HBK page. 1000 kN rated capacity = 1,000 kN (101.9716 t mass equivalent at standard gravity); compression 100 kN rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression 250 kN rated capacity = 250 kN (25.4929 t mass equivalent at standard gravity); compression 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression 2.5 kN rated capacity = 2.5 kN (254.9291 kg mass equivalent at standard gravity); compression 500 kN rated capacity = 500 kN (50.9858 t mass equivalent at standard gravity); compression 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression
Force range Not specified 0–1000000 N 0–100000 N 0–10000 N 0–250000 N 0–25000 N 0–2500 N 0–500000 N 0–50000 N 0–5000 N
Interfaces Not specified ethercat ethernet ethercat ethernet ethernet ethernet profinet ethernet ethernet
Accuracy (% FSO) Not specified 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 %
ADC sampling rate Not specified 19200 samples/s 19200 samples/s 19200 samples/s 40000 samples/s 19200 samples/s 19200 samples/s 19200 samples/s 450 samples/s 450 samples/s
source_sampling_rate_basis Not specified MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth
Status Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

ISO 376 Class 00 is specified from 10% to 100% of nominal force. It is a classification, not a zero-percent error claim.

C15 is intended for compression. The manufacturer identifies U15 for tensile and compressive reference measurements.

No. Output above 4 mV/V is specified from 25 kN, and rated-output adjustment is available as an option.

Yes. Measurement-chain calibration is available on request, rather than only calibrating the transducer separately.

The manufacturer specifies IP67 and a hermetically welded construction for C15.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words