C2 Force
C2: sensors and measurement devices by HBK for force.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
| Ordering options and constraints | K-C2- — capacity: 112 lbf, 225 lbf, 450 lbf, 1.12 klbf, 2.25 klbf, 4.5 klbf, 11.2 klbf, 22.5 klbf, 45 klbf; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link; height_without_accessories: 1.18 in, 1.89 in, 2.36 in; diameter_without_cable_or_plug: 4.52755 in, 1.9685 in, 3.5433 in; constraints: [] |
|---|
Range across models
The span covered by the models of the series together — not the range of each model.
| Operating temperature | -20–60 °C |
|---|---|
| Interfaces | io_link |
| Force range | 0–50000 N |
| Protection class (DIN EN 60529) | ip67 |
| ADC sampling rate | 450–40000 samples/s |
| Nominal force capacity | 500–200000 N |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-C2/100KN eli-m-38ed53df1a3917a16f83388d | 1-C2/10KN eli-m-a61531bb5f5815214b74bc54 | 1-C2/1KN eli-m-2b0b1a5c0009d37feeda6dfd | 1-C2/200KN eli-m-e88531348a482d39d9747318 | 1-C2/20KN eli-m-22dffa41bc06ce9361c46664 | 1-C2/2KN eli-m-1b9fa4fa4fdb5b7e1ccc329a | 1-C2/500N eli-m-48a484e4ec2e0e1223489bc1 | 1-C2/50KN eli-m-6c8216f732548620898badfe | 1-C2/5KN eli-m-ed20dec4364da69f5edf7db6 | C2-100000N eli-m-e40d42d985a7c2dc4522ffcc | C2-10000N eli-m-7a0037274bdb138dcd680108 | C2-1000N eli-m-840a18a337a77fe0738e7560 | C2-200000N eli-m-6c65778f9711ed4cbbe979e1 | C2-20000N eli-m-98d945e58e26ecd7f7e0fa0b | C2-2000N eli-m-0f508f05c3b93d4dcbef1ff8 | C2-50000N eli-m-a77a6c0ec323e4822b611c90 | C2-5000N eli-m-c2f0f82f8f610459bfd608d9 | C2-500N eli-m-24a5055bccf82ed0bb784fa1 | K-C2- · 1 kN eli-m-51c1f2ade3d9120b2bb834aa | K-C2- · 10 kN eli-m-e713213f6ecf265ced92026e | K-C2- · 100 kN eli-m-14c86b3bfa21f2b74a5df8fc | K-C2- · 2 kN eli-m-8076970db4745d4124398072 | K-C2- · 20 kN eli-m-807ce2b53cb6c1d3db227c76 | K-C2- · 200 kN eli-m-8f12fcc45548c9912db977a3 | K-C2- · 5 kN eli-m-13878e3ef0143145e753c76b | K-C2- · 50 kN eli-m-20cdea1925e502f66e56c7eb | K-C2- · 500 N eli-m-d04b480e12f301f546070b79 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating temperature | -20–60 °C | -30–85 °C | -20–60 °C | -20–60 °C | -20–60 °C | -10–60 °C | -20–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -10–60 °C | -20–60 °C | -20–60 °C | -10–60 °C | -30–85 °C | -10–60 °C | -30–85 °C | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ethercat | ethernet | ethernet | ethernet | ethercat | ethernet | io_link | ethercat | ethercat | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | 0–100000 N | 0–10000 N | 0–1000 N | 0–200000 N | 0–20000 N | 0–2000 N | 0–500 N | 0–50000 N | 0–5000 N | 0–100000 N | 0–10000 N | 0–1000 N | 0–200000 N | 0–20000 N | 0–2000 N | 0–50000 N | 0–5000 N | 0–500 N | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Protection class (DIN EN 60529) | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | ip67 | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| interface_specification | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | RS422 / RS485 | Digital I/O | Analog 0-10V | 4-20mA | RS422 / RS485 | RS422 / RS485 | Digital I/O | Digital I/O | Analog 0-10V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| quantity_specification | Maximum capacity (nominal load): 22.5 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in | Maximum capacity (nominal load): 2.25 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 225 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 45 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in | Maximum capacity (nominal load): 4.5 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in | Maximum capacity (nominal load): 450 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 112 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | Maximum capacity (nominal load): 11.2 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in | Maximum capacity (nominal load): 1.12 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in | 100000 N rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression | 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression | 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression | 200000 N rated capacity = 200 kN (20.3943 t mass equivalent at standard gravity); compression | 20000 N rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression | 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression | 50000 N rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression | 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression | 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Force range | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1111 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 450 samples/s | 1111 samples/s | 19200 samples/s | 450 samples/s | 1111 samples/s | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| source_sampling_rate_basis | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | DMP41 selectable result rate, intended for reference and calibration measurements | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | DMP41 selectable result rate, intended for reference and calibration measurements | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Accuracy (% FSO) | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | 0.2 % | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Selected configuration options | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1 kN nominal force capacity | 10 kN nominal force capacity | 100 kN nominal force capacity | 2 kN nominal force capacity | 20 kN nominal force capacity | 200 kN nominal force capacity | 5 kN nominal force capacity | 50 kN nominal force capacity | 500 N nominal force capacity |
| Nominal force capacity | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 1000 N | 10000 N | 100000 N | 2000 N | 20000 N | 200000 N | 5000 N | 50000 N | 500 N |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — K-C2- · 1 kN (opens in a new tab) | PDF — K-C2- · 10 kN (opens in a new tab) | PDF — K-C2- · 100 kN (opens in a new tab) | PDF — K-C2- · 2 kN (opens in a new tab) | PDF — K-C2- · 20 kN (opens in a new tab) | PDF — K-C2- · 200 kN (opens in a new tab) | PDF — K-C2- · 5 kN (opens in a new tab) | PDF — K-C2- · 50 kN (opens in a new tab) | PDF — K-C2- · 500 N (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
C2 measures compressive force in static and dynamic applications. It is not specified as a tension/compression transducer.
No. Passive and integrated-amplifier versions include voltage, current or IO-Link options. The order code determines the output.
The C2 datasheet specifies IP67. Select suitable system connections and cabling.
No. TEDS is an ordering option; check the configuration code rather than assuming it is present.
The documented versions with and without an amplifier have the same external dimensions and accuracy class. The difference is a passive bridge versus an amplified output. The receiving system still needs the corresponding input type.
Get a quote or advice
Tell us what you need and an engineer will come back to you.