Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for C2
Ordering options and constraints K-C2- — capacity: 112 lbf, 225 lbf, 450 lbf, 1.12 klbf, 2.25 klbf, 4.5 klbf, 11.2 klbf, 22.5 klbf, 45 klbf; output_signal: mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link; height_without_accessories: 1.18 in, 1.89 in, 2.36 in; diameter_without_cable_or_plug: 4.52755 in, 1.9685 in, 3.5433 in; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of C2
Operating temperature -20–60 °C
Interfaces io_link
Force range 0–50000 N
Protection class (DIN EN 60529) ip67
ADC sampling rate 450–40000 samples/s
Nominal force capacity 500–200000 N

Models in the series

One column per model: what differs between the models of the series.

Models of C2 compared by parameter
Parameter 1-C2/100KN eli-m-38ed53df1a3917a16f83388d 1-C2/10KN eli-m-a61531bb5f5815214b74bc54 1-C2/1KN eli-m-2b0b1a5c0009d37feeda6dfd 1-C2/200KN eli-m-e88531348a482d39d9747318 1-C2/20KN eli-m-22dffa41bc06ce9361c46664 1-C2/2KN eli-m-1b9fa4fa4fdb5b7e1ccc329a 1-C2/500N eli-m-48a484e4ec2e0e1223489bc1 1-C2/50KN eli-m-6c8216f732548620898badfe 1-C2/5KN eli-m-ed20dec4364da69f5edf7db6 C2-100000N eli-m-e40d42d985a7c2dc4522ffcc C2-10000N eli-m-7a0037274bdb138dcd680108 C2-1000N eli-m-840a18a337a77fe0738e7560 C2-200000N eli-m-6c65778f9711ed4cbbe979e1 C2-20000N eli-m-98d945e58e26ecd7f7e0fa0b C2-2000N eli-m-0f508f05c3b93d4dcbef1ff8 C2-50000N eli-m-a77a6c0ec323e4822b611c90 C2-5000N eli-m-c2f0f82f8f610459bfd608d9 C2-500N eli-m-24a5055bccf82ed0bb784fa1 K-C2- · 1 kN eli-m-51c1f2ade3d9120b2bb834aa K-C2- · 10 kN eli-m-e713213f6ecf265ced92026e K-C2- · 100 kN eli-m-14c86b3bfa21f2b74a5df8fc K-C2- · 2 kN eli-m-8076970db4745d4124398072 K-C2- · 20 kN eli-m-807ce2b53cb6c1d3db227c76 K-C2- · 200 kN eli-m-8f12fcc45548c9912db977a3 K-C2- · 5 kN eli-m-13878e3ef0143145e753c76b K-C2- · 50 kN eli-m-20cdea1925e502f66e56c7eb K-C2- · 500 N eli-m-d04b480e12f301f546070b79
Operating temperature -20–60 °C -30–85 °C -20–60 °C -20–60 °C -20–60 °C -10–60 °C -20–60 °C -10–60 °C -10–60 °C -10–60 °C -10–60 °C -10–60 °C -20–60 °C -20–60 °C -10–60 °C -30–85 °C -10–60 °C -30–85 °C Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified ethercat ethernet ethernet ethernet ethercat ethernet io_link ethercat ethercat Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Force range 0–100000 N 0–10000 N 0–1000 N 0–200000 N 0–20000 N 0–2000 N 0–500 N 0–50000 N 0–5000 N 0–100000 N 0–10000 N 0–1000 N 0–200000 N 0–20000 N 0–2000 N 0–50000 N 0–5000 N 0–500 N Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Protection class (DIN EN 60529) ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 ip67 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
interface_specification Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown RS422 / RS485 Digital I/O Analog 0-10V 4-20mA RS422 / RS485 RS422 / RS485 Digital I/O Digital I/O Analog 0-10V Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
quantity_specification Maximum capacity (nominal load): 22.5 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in Maximum capacity (nominal load): 2.25 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in Maximum capacity (nominal load): 225 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in Maximum capacity (nominal load): 45 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 2.36 in; Diameter (without cable or plug): 4.52755 in Maximum capacity (nominal load): 4.5 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in Maximum capacity (nominal load): 450 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in Maximum capacity (nominal load): 112 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in Maximum capacity (nominal load): 11.2 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 3.5433 in Maximum capacity (nominal load): 1.12 klbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.18 in; Diameter (without cable or plug): 1.9685 in 100000 N rated capacity = 100 kN (10.1972 t mass equivalent at standard gravity); compression 10000 N rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression 1000 N rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression 200000 N rated capacity = 200 kN (20.3943 t mass equivalent at standard gravity); compression 20000 N rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression 2000 N rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression 50000 N rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression 5000 N rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression 500 N rated capacity = 500 N (50.9858 kg mass equivalent at standard gravity); compression Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1111 samples/s 40000 samples/s 40000 samples/s 40000 samples/s 450 samples/s 1111 samples/s 19200 samples/s 450 samples/s 1111 samples/s Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
source_sampling_rate_basis Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted DMP41 selectable result rate, intended for reference and calibration measurements ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted DMP41 selectable result rate, intended for reference and calibration measurements The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted The analog output bandwidth and configured filter define usable dynamics; no unsupported digital rate is asserted Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1 kN nominal force capacity 10 kN nominal force capacity 100 kN nominal force capacity 2 kN nominal force capacity 20 kN nominal force capacity 200 kN nominal force capacity 5 kN nominal force capacity 50 kN nominal force capacity 500 N nominal force capacity
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1000 N 10000 N 100000 N 2000 N 20000 N 200000 N 5000 N 50000 N 500 N
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — K-C2- · 1 kN (opens in a new tab) PDF — K-C2- · 10 kN (opens in a new tab) PDF — K-C2- · 100 kN (opens in a new tab) PDF — K-C2- · 2 kN (opens in a new tab) PDF — K-C2- · 20 kN (opens in a new tab) PDF — K-C2- · 200 kN (opens in a new tab) PDF — K-C2- · 5 kN (opens in a new tab) PDF — K-C2- · 50 kN (opens in a new tab) PDF — K-C2- · 500 N (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

C2 measures compressive force in static and dynamic applications. It is not specified as a tension/compression transducer.

No. Passive and integrated-amplifier versions include voltage, current or IO-Link options. The order code determines the output.

The C2 datasheet specifies IP67. Select suitable system connections and cabling.

No. TEDS is an ordering option; check the configuration code rather than assuming it is present.

The documented versions with and without an amplifier have the same external dimensions and accuracy class. The difference is a passive bridge versus an amplified output. The receiving system still needs the corresponding input type.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words