colorCONTROL MFA
colorCONTROL MFA: sensors and measurement devices by Micro-Epsilon for sensors.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Measuring rate | 30–100 Hz |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | MFA-14 eli-m-cbbb71da5187b79c826a17cb | MFA-21 eli-m-e4e6c7bd31f1791daad42492 | MFA-28 eli-m-8340f9cd6b4d24f65d4747e5 | MFA-7 eli-m-421174125cb08cb566ab58d4 |
|---|---|---|---|---|
| Interfaces | rs232 | rs422 | rs422 | rs232 |
| Color repeatability ΔE | 2.5e-05 ΔE | 2.5e-05 ΔE | 2.5e-05 ΔE | 2.5e-05 ΔE |
| Spectral range | 400–700 nm | 400–700 nm | 400–700 nm | 400–700 nm |
| quantity_specification | 14-channel official MFA analyzer; 400–700 nm spectral range, up to 50,000 lx input and model-dependent rate below 59 Hz. | 21-channel official MFA analyzer; 400–700 nm spectral range, up to 50,000 lx input and model-dependent rate below 40 Hz. | 28-channel official MFA analyzer; 400–700 nm spectral range, up to 50,000 lx input and model-dependent rate below 30 Hz. | 7-channel official MFA analyzer; 400–700 nm spectral range, up to 50,000 lx input and model-dependent rate below 100 Hz. |
| interface_specification | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 | RS422 / RS485 |
| Measuring rate | 59 Hz | 40 Hz | 30 Hz | 100 Hz |
| Status | Active | Active | Active | Active |
| Datasheet | PDF — MFA-14 (opens in a new tab) | PDF — MFA-21 (opens in a new tab) | PDF — MFA-28 (opens in a new tab) | PDF — MFA-7 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
Relative color, intensity and function testing of sources such as LEDs, including multiple simultaneous inspection positions using MFS heads.
No. MFA-7, MFA-14, MFA-21 and MFA-28 have different channel counts. Select for the required inspection positions.
No. Rates differ by model under specified baud rate/message content. Adding CCT or dominant wavelength reduces rate.
No. The controller is IP20; MFS ratings vary by head. Do not transfer head ratings to controller or vice versa.
Use compatible MFS heads/fibers and tabulated working distance. Preserve bend radius and protect unused optical connections.
Get a quote or advice
Tell us what you need and an engineer will come back to you.