1-P8AP/100B-001
From the P8AP series
P8AP: sensors and measurement devices by HBK for sensors.
- Pressure reference
- v_9030f6c8e098622f
Technical specification
Every engineering figure, laid out to scan quickly
| Pressure reference | v_9030f6c8e098622f |
|---|---|
| interface_specification | Unknown |
| Operating temperature | -40–80 °C |
| Protection class (DIN EN 60529) | ip67 |
| quantity_specification | 0 to 100 bar nominal; Absolute pressure; Passive strain gauge; Multi purpose; Fixed cable |
| source_linearity_basis | Official indexed accuracy class: 0.3%. |
| source_sampling_rate_limited_by_readout | True |
| source_pressure_measurement_principle | Absolute pressure |
| source_sampling_rate_basis | The selected bridge amplifier and DAQ define the digital sample rate. |
| Pressure range | 0–100 bar |
| source_repeatability_basis | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. |
| source_pressure_output | Passive strain gauge |
| source_pressure_accuracy_class_percent | 0.3 % (source basis mandatory) |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.