Skip to content

PW15AH/PW15PH Force

PW15AH/PW15PH: sensors and measurement devices by HBK for force.

This series on the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of PW15AH/PW15PH
Force range 0–980.665 N

Models in the series

One column per model: what differs between the models of the series.

Models of PW15AH/PW15PH compared by parameter
Parameter PW15AH/PW15PH-100kg eli-m-64525f0131df467d11dc58f7 PW15AH/PW15PH-10kg eli-m-660616aad9dbd167c551ef99 PW15AH/PW15PH-20kg eli-m-c81d05cac0899336cc570700 PW15AH/PW15PH-50kg eli-m-358131ef247fc8fdaa6b61a3
quantity_specification 100 kg rated capacity = 980.665 N (100 kg mass equivalent at standard gravity); compression 10 kg rated capacity = 98.0665 N (10 kg mass equivalent at standard gravity); compression 20 kg rated capacity = 196.133 N (20 kg mass equivalent at standard gravity); compression 50 kg rated capacity = 490.3325 N (50 kg mass equivalent at standard gravity); compression
ADC sampling rate 19200 samples/s 19200 samples/s 19200 samples/s 19200 samples/s
Interfaces ethercat ethernet ethercat ethercat
Force range 0–980.665 N 0–98.06649999999999 N 0–196.133 N 0–490.3325 N
source_sampling_rate_basis LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth LCMC analog bandwidth is variant- and filter-dependent; confirm it for the ordered chain MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth
Operating temperature -10–50 °C -10–50 °C -10–50 °C -10–50 °C
interface_specification RS422 / RS485 4-20mA RS422 / RS485 Analog 0-10V
Status Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

PW15PH provides a plug system for quick replacement; select the appropriate connection configuration.

Maximum capacities range from 10 to 100 kg, depending on the model.

Passive mV/V. IO-Link requires an appropriate LCMC measurement chain.

IP68/IP69K is specified; use the matching cable and connector configuration.

Static and dynamic filling or dosing, and platform scale construction.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words