PW16A-300kg
From the PW16A series
PW16A: sensors and measurement devices by HBK for force.
- Force range
- 0–2941.995 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | 0–2941.995 N |
|---|---|
| Interfaces | ethercat |
| interface_specification | Analog 0-10V |
| Operating temperature | -10–50 °C |
| Protection class (DIN EN 60529) | ip67 |
| quantity_specification | 300 kg rated capacity = 2.942 kN (300 kg mass equivalent at standard gravity); compression |
| ADC sampling rate | 19200 samples/s |
| Ordering options and constraints | K-PW16A — capacity: 66.14 lb, 110.2 lb, 165.3 lb, 220.4 lb, 330.7 lb, 440.9 lb, 551.1 lb, 661.4 lb, 1102 lb, 1455 lb; accuracy_class: C4; minimum_verification_interval_vmin: 5 g, 10 g, 20 g, 50 g; certification: OIML, NTEP (US), ATEX/IECEx; constraints: [] |
| source_sampling_rate_basis | LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Interfaces | ethernet |
| source_sampling_rate_basis | LCMC digital update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Interfaces | io_link |
| interface_specification | 4-20mA |
| interface_specification | Digital I/O |
| interface_specification | RS422 / RS485 |
| source_sampling_rate_basis | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| ADC sampling rate | 40000 samples/s |
| Interfaces | profinet |
| source_sampling_rate_basis | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| source_sampling_rate_basis | LCMC analog bandwidth is variant- and filter-dependent; confirm it for the ordered chain |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.