Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of T100/T110
Torque range -10000–10000 Nm
ADC sampling rate 1000–20000 samples/s
Maximum rotational speed 12000–25000 rpm

Models in the series

One column per model: what differs between the models of the series.

Models of T100/T110 compared by parameter
Parameter T100/T110-100Nm eli-m-bacf0b283af33a14dcc212a5 T100/T110-10kNm eli-m-b8de1b17393e71845750a677 T100/T110-1kNm eli-m-5dda9d9ea56cf213dc60fcde T100/T110-200Nm eli-m-a62f7450d879cdba2eae3c8e T100/T110-2kNm eli-m-c2117e8c622346bcdf586ef3 T100/T110-3kNm eli-m-7fe791d76b4368867afba90a T100/T110-500Nm eli-m-14afdb664472ec693783ca29 T100/T110-50Nm eli-m-afdfb38b5dff2f56567af19e T100/T110-5kNm eli-m-0c054591d3b3d53bbd969f09
source_torque_speed_measurement True True True True True True True True True
interface_specification Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
quantity_specification ±100 Nm rated torque; rotating installation; maximum 25,000 rpm ±10 kNm rated torque; rotating installation; maximum 12,000 rpm ±1 kNm rated torque; rotating installation; maximum 22,000 rpm ±200 Nm rated torque; rotating installation; maximum 25,000 rpm ±2 kNm rated torque; rotating installation; maximum 14,000 rpm ±3 kNm rated torque; rotating installation; maximum 14,000 rpm ±500 Nm rated torque; rotating installation; maximum 22,000 rpm ±50 Nm rated torque; rotating installation; maximum 25,000 rpm ±5 kNm rated torque; rotating installation; maximum 12,000 rpm
Torque range -100–100 Nm -10000–10000 Nm -1000–1000 Nm -200–200 Nm -2000–2000 Nm -3000–3000 Nm -500–500 Nm -50–50 Nm -5000–5000 Nm
ADC sampling rate 4000 samples/s 1000 samples/s 20000 samples/s 4000 samples/s 20000 samples/s 20000 samples/s 4000 samples/s 1000 samples/s 1000 samples/s
Accuracy (% FSO) 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 %
Interfaces ethercat ethercat ethernet ethercat profinet ethercat ethernet profinet profinet
source_sampling_rate_basis TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-PN bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors TIM-EC bus cycle; transducer bandwidth and selected filters remain limiting factors TIM40 bus cycle; transducer bandwidth and selected filters remain limiting factors
Maximum rotational speed 25000 rpm 12000 rpm 22000 rpm 25000 rpm 14000 rpm 14000 rpm 22000 rpm 25000 rpm 12000 rpm
Status Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The rotor contains the measuring body, strain gauges and transmitting electronics. The stator receives and conditions the signal and provides output connections. They are two system components.

No. The stator datasheet specifies 160 kHz sampling and bandwidth up to 15 kHz at −3 dB. Keep the two definitions separate.

The stator includes a web server for parameters and signal plotting. Integrating data into a measurement application still requires the appropriate output interface and processing environment.

Yes. The manual describes static and dynamic torque measurement on stationary and rotating shafts. Suitability still depends on rotor, capacity and installation conditions.

Contactless energy and signal transmission require appropriate alignment. The manual provides alignment indication and positioning instructions; mechanical assembly alone is insufficient.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words