T22 Torque
T22: sensors and measurement devices by HBK for torque.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Maximum rotational speed | 9000–20000 rpm |
|---|
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-T22/0.5NM eli-m-8a3ddb09665fb8e68117a950 | 1-T22/100NM eli-m-8930f0648356d588ac961c22 | 1-T22/10NM eli-m-47bc6e6f498324df23a2a6e0 | 1-T22/1KNM eli-m-fdb0abefacc3b174cd7a69c0 | 1-T22/1NM eli-m-cfdaf5f68709cc09a736205c | 1-T22/200NM eli-m-d746d2d4c80e3b235f1e7461 | 1-T22/20NM eli-m-9c14fb66e7bcb3cb7cd2f678 | 1-T22/2NM eli-m-f17a6e333930fff5a3a082ac | 1-T22/500NM eli-m-98664af71eef3bb28bec5993 | 1-T22/50NM eli-m-6f891db5adcae6346c330395 | 1-T22/5NM eli-m-c35a092341234205012e7304 | T22-100Nm eli-m-6c25b82d5c2360859b181c51 | T22-10Nm eli-m-d07257df9447c223616dbe44 | T22-1kNm eli-m-a9c7c6e18d5fa7cb36c30219 | T22-1Nm eli-m-bc4e8230b09e48390140890f | T22-200Nm eli-m-a6032cee5e79dd82c31874a1 | T22-20Nm eli-m-b21b4adf9fb4456091d2caca | T22-2Nm eli-m-15571a23b8f3e3e9b46e12de | T22-500Nm eli-m-16956d38f064fdd17b2d6b0f | T22-500Nmm eli-m-7d6a95ca6f995bfd9858becf | T22-50Nm eli-m-5aa50ee69b5da08fcf345d69 | T22-5Nm eli-m-a54c20b6cba10b264cea31e6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Torque range | -0.5–0.5 Nm | -100–100 Nm | -10–10 Nm | -1000–1000 Nm | -1–1 Nm | -200–200 Nm | -20–20 Nm | -2–2 Nm | -500–500 Nm | -50–50 Nm | -5–5 Nm | -100–100 Nm | -10–10 Nm | -1000–1000 Nm | -1–1 Nm | -200–200 Nm | -20–20 Nm | -2–2 Nm | -500–500 Nm | -0.5–0.5 Nm | -50–50 Nm | -5–5 Nm |
| interface_specification | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| quantity_specification | Actions: Not sellable online; Measurement range: 4.43 in-lb; Nominal rotational speed: 20000 rpm; Size (length): 2.6 in | Actions: Not sellable online; Measurement range: 885 in-lb; Nominal rotational speed: 16000 rpm; Size (length): 3.54 in | Actions: Not sellable online; Measurement range: 88.5 in-lb; Nominal rotational speed: 12000 rpm; Size (length): 3.15 in | Actions: Not sellable online; Measurement range: 8851 in-lb; Nominal rotational speed: 9000 rpm; Size (length): 4.72 in | Actions: Not sellable online; Measurement range: 8.85 in-lb; Nominal rotational speed: 20000 rpm; Size (length): 2.6 in | Actions: Not sellable online; Measurement range: 1770 in-lb; Nominal rotational speed: 16000 rpm; Size (length): 3.54 in | Actions: Not sellable online; Measurement range: 177 in-lb; Nominal rotational speed: 12000 rpm; Size (length): 3.15 in | Actions: Not sellable online; Measurement range: 17.7 in-lb; Nominal rotational speed: 20000 rpm; Size (length): 2.6 in | Actions: Not sellable online; Measurement range: 4425 in-lb; Nominal rotational speed: 9000 rpm; Size (length): 4.72 in | Actions: Not sellable online; Measurement range: 443 in-lb; Nominal rotational speed: 16000 rpm; Size (length): 3.54 in | Actions: Not sellable online; Measurement range: 44.3 in-lb; Nominal rotational speed: 12000 rpm; Size (length): 3.15 in | ±100 Nm rated torque; rotating installation; maximum 16,000 rpm | ±10 Nm rated torque; rotating installation; maximum 12,000 rpm | ±1 kNm rated torque; rotating installation; maximum 9,000 rpm | ±1 Nm rated torque; rotating installation; maximum 20,000 rpm | ±200 Nm rated torque; rotating installation; maximum 16,000 rpm | ±20 Nm rated torque; rotating installation; maximum 12,000 rpm | ±2 Nm rated torque; rotating installation; maximum 20,000 rpm | ±500 Nm rated torque; rotating installation; maximum 9,000 rpm | ±500 Nmm rated torque; rotating installation; maximum 20,000 rpm | ±50 Nm rated torque; rotating installation; maximum 16,000 rpm | ±5 Nm rated torque; rotating installation; maximum 12,000 rpm |
| Maximum rotational speed | 20000 rpm | 16000 rpm | 12000 rpm | 9000 rpm | 20000 rpm | 16000 rpm | 12000 rpm | 20000 rpm | 9000 rpm | 16000 rpm | 12000 rpm | 16000 rpm | 12000 rpm | 9000 rpm | 20000 rpm | 16000 rpm | 12000 rpm | 20000 rpm | 9000 rpm | 20000 rpm | 16000 rpm | 12000 rpm |
| Torque range | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Interfaces | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | ethercat | ethernet | ethercat | ethernet | ethernet | ethercat | ethercat | ethercat | ethernet | ethercat | ethercat |
| ADC sampling rate | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s | 40000 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The manual specifies ±5 V voltage and 10±8 mA current outputs. Do not automatically relabel them as 0–10 V or 4–20 mA.
The manual states that couplings and transducer are delivered separately. Select the coupling and installation instructions for shaft dimensions and load limits.
Yes. The manual permits different orientations. Vertical or angled arrangements require support for additional elements and compliance with axial-load and bending-moment limits.
No. Follow both coupling limits and the transducer’s longitudinal-force, lateral-force and bending-moment limits.
Use a shielded, low-capacitance cable, maintain stable connections and sound insulation, and implement shielding according to manufacturer instructions. Do not run the measuring cable parallel to power and control cables without the appropriate separation and protection.
Get a quote or advice
Tell us what you need and an engineer will come back to you.