U10S Force
U10S: sensors and measurement devices by HBK for force.
This series on the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Force range | -450000–450000 N |
|---|---|
| ADC sampling rate | 450–40000 samples/s |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | U10S-125kN eli-m-f6c07ce9189f98e6e18b8b1d | U10S-12p5kN eli-m-5c0e3d245b75a7f732322bbd | U10S-1p25kN eli-m-755e99f90825854164361498 | U10S-225kN eli-m-66395317a47f104a9e68d36a | U10S-25kN eli-m-2cff95f7e1b171c3125ca74e | U10S-2p5kN eli-m-20f2fe89b8e7bbf2890e7436 | U10S-450kN eli-m-2803cb3b5081c271cb0f6697 | U10S-50kN eli-m-911d7a4f3b61e277de8111d3 | U10S-5kN eli-m-21fe88df382e9adb09c77fba |
|---|---|---|---|---|---|---|---|---|---|
| source_sampling_rate_basis | DMP41 selectable result rate, intended for reference and calibration measurements | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| interface_specification | Analog 0-10V | RS422 / RS485 | Digital I/O | Analog 0-10V | Analog 0-10V | Analog 0-10V | RS422 / RS485 | Digital I/O | Analog 0-10V |
| Accuracy (% FSO) | 0.06 % | 0.06 % | 0.06 % | 0.06 % | 0.06 % | 0.06 % | 0.06 % | 0.06 % | 0.06 % |
| Interfaces | ethernet | ethernet | ethernet | ethernet | ethercat | profinet | ethercat | profinet | ethercat |
| Force range | -125000–125000 N | -12500–12500 N | -1250–1250 N | -225000–225000 N | -25000–25000 N | -2500–2500 N | -450000–450000 N | -50000–50000 N | -5000–5000 N |
| quantity_specification | 125 kN rated capacity = 125 kN (12.7465 t mass equivalent at standard gravity); compression and tension | 12.5 kN rated capacity = 12.5 kN (1.2746 t mass equivalent at standard gravity); compression and tension | 1.25 kN rated capacity = 1.25 kN (127.4645 kg mass equivalent at standard gravity); compression and tension | 225 kN rated capacity = 225 kN (22.9436 t mass equivalent at standard gravity); compression and tension | 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression and tension | 2.5 kN rated capacity = 2.5 kN (254.9291 kg mass equivalent at standard gravity); compression and tension | 450 kN rated capacity = 450 kN (45.8872 t mass equivalent at standard gravity); compression and tension | 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression and tension | 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension |
| ADC sampling rate | 40000 samples/s | 40000 samples/s | 19200 samples/s | 19200 samples/s | 450 samples/s | 19200 samples/s | 450 samples/s | 450 samples/s | 450 samples/s |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
U10S uses inch-based UNF threads; U10M uses metric threads.
Yes. The U10 family, including U10S, measures tensile and compressive forces.
No. The U10S table specifies different accuracy classes by capacity. Use the selected model’s value.
No. The datasheet specifies TEDS only when transducer-identification option T is selected.
The data sheet specifies 5 V reference excitation and a 0.5–12 V operating excitation range. This is the measuring-bridge excitation, not the sensor signal output. Match the six-wire connection and amplifier input as well.