Parameter 2667 eli-m-69579316c6c3ac8fec2901c4
Frequency response 1–100000 Hz
Status Active
Datasheet PDF — 2667 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It converts a charge accelerometer signal to voltage for vibration measurement. Its differential input is documented for balanced sensors such as 5704.

The manual specifies II 3G Ex ic IIC T6 Gc with −40 to +70 °C ambient temperature. Match the chain to certificate conditions rather than assuming approval for every hazardous area.

No. The manual requires the specified interface terminals to connect to certified barriers or isolators in the safe area. Follow the approved chain drawing.

By suffix: the table includes 1 or 10 mV/pC gains and different filter bands. Do not assign the widest-band version performance to every version.

The amplifier itself is IP20, and the manufacturer requires DIN-rail mounting inside a suitable shielded IP65 Ex junction box. Preserve the documented isolation, grounding and cabling arrangements.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words