| Parameter | 2688 eli-m-66b4418b5df566b65eccc32f |
|---|---|
| Frequency response | 1–100000 Hz |
| Status | Active |
| Datasheet | PDF — 2688 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
It converts piezoelectric sensor signals to low-impedance voltage for vibration monitoring and is also designed for radiation areas in nuclear power stations.
The manual describes a differential input with balanced accelerometers such as 8315 and 8324. Preserve the appropriate cable and shielding arrangement.
No. The version table lists 1, 5 or 10 mV/pC. Version 2688-R-003 has 0 V DC offset, while the other listed versions have −10 V.
The general table states 1 Hz to 100 kHz at ±1 dB. When ordering, check the exact version, charge gain and input-loading conditions.
The amplifier itself is IP20. The manufacturer requires DIN-rail installation in a shielded IP65 junction box and double-screened cables according to the wiring instructions.