Charge amplifier 2688 Vibration controllers

Charge amplifier 2688: measurement controllers by Brüel & Kjær Vibro for vibration controllers.

Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of Charge amplifier 2688 compared by parameter
Parameter 2688 eli-m-66b4418b5df566b65eccc32f
Frequency response 1–100000 Hz
Status Active
Datasheet PDF — 2688 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It converts piezoelectric sensor signals to low-impedance voltage for vibration monitoring and is also designed for radiation areas in nuclear power stations.

The manual describes a differential input with balanced accelerometers such as 8315 and 8324. Preserve the appropriate cable and shielding arrangement.

No. The version table lists 1, 5 or 10 mV/pC. Version 2688-R-003 has 0 V DC offset, while the other listed versions have −10 V.

The general table states 1 Hz to 100 kHz at ±1 dB. When ordering, check the exact version, charge gain and input-loading conditions.

The amplifier itself is IP20. The manufacturer requires DIN-rail installation in a shielded IP65 junction box and double-screened cables according to the wiring instructions.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words