Parameter DDAU3 eli-m-33e0d24600a030d6a1b82720
Number of measurement channels 12
Status Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The page lists 12 dynamic channels, four speed/DC inputs and eight 4–20 mA process inputs. These groups serve different functions.

The manufacturer defines 80 kHz as the dynamic-channel frequency-range limit. Sampling rate is a different specification; the two must not be substituted.

Yes. The manufacturer specifies integration with SCADA, PLC and OSIsoft PI systems.

Yes. Its internal storage retains data when the network connection is inactive.

The August 2026 data sheet specifies 204.8 kHz for AC/DC channels, 8 kHz for Speed/DC inputs used as DC channels, and 4 kHz for 4–20 mA inputs. Bandwidth is separate; the dynamic-channel 80 kHz bandwidth is not its sample rate.

No. State-dependent limits can change according to value ranges of other descriptors. Define operating states, thresholds and time hysteresis explicitly; connecting a sensor alone does not define the alarm policy.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words